1634 Coaxlink Duo PCIe/104-MIL Power Distribution Scheme
The power distribution scheme has two distinct distribution networks:
●
The main power distribution network
●
The camera power distribution network
NOTE
The fuses are not serviceable! When blown, the card must be returned to the
factory.
NOTE
PTCs and electronic fuses are self-resettable fuses.
NOTE
The Coaxlink card can be operated without applying power to the camera
power distribution network.
The
main power distribution network
delivers power to
all the on-board electronic devices
including FPGA, memory chips, CoaXPress transceivers, I/O drivers and receivers, fan motor.
It also de3.3 V and +12 V to the I/O module plugged on the extension connector:
●
The +3.3 V is used for powering the on-board electronics: I/O drivers, I/O receivers
●
The +12 V is used for delivering power on the I/O connector. A PTC inserted at the input
prevents potential fire hazards.
The network is fed by the Host PC through the +12 V power rail of the PCIe/104 connector. A
protection fuse prevents potential fire hazards. The
+12 V LED
indicates the presence of +12 V
after the protection fuse.