Euphonix TT007 Operation Manual
TT007 Menu Modes
11
Chapter 2: TT007 Menu Modes
2.1
Port Mode Menu
To access Port Mode from the Port Assignments Display:
1.
Press any Menu key.
2.
Scroll through the list with the
PREV
and
NEXT
keys until
PORT MODE
is
displayed.
3.
Press the
ENTER
key.
You can also press any of the dedicated, front panel Port keys. Depending on the Port being
viewed, the display shows a different status to indicate that Port’s current assignment.
The possible assignments are:
Off
Port is inactive (off-line).
Controller
Port can pass both synchronization data and transport commands (FF, Rew, Stop, etc.)
to/from the connected device. Transport commands relayed from the device, are returned
to the Master Port. See Section A.2 -
Explanation of Controllers
for more information.
Slave
Port passes
only
synchronization data (timecode) to the connected device.
Master
Sets port as the
master
synchronization source for the entire system. Any timecode sync
source from the Master device will be transmitted to all other TT007 ports selected as
either Slave or Controller. The Master device’s transport may be controlled locally via
its own front panel or remotely via other controller devices attached to the TT007.
The
PREV
and
NEXT
keys scroll through the Port list. The
UP
and
DOWN
keys (or
the Data Wheel) select assignment options. Pressing
EXIT
returns to the default display.
ENTER
has no function in this menu.
NOTE:
Selecting a Port as Master forces any previous Master Port selection off-line. Designating
a Master is immediate when selected in the Port menu. If the TT007 is configured
without a Master Port, the
EXIT
and
ENTER
keys flash alternately to alert the user
that no Master Port has been defined for this preset.