Euphonix TT007

Machine Control Hub for System 5

and CS Series Consoles

Operation Manual

Document Revision

: 2.0

Release Date

: February, 2002

TT007 Version

: 4

Part Number

: 840-05044-03

Euphonix Inc.

220 Portage Ave.
Palo Alto, California 94306
Phone: 650-855-0400
Fax: 650-855-0410
Web:

http://www.euphonix.com

e-mail: [email protected]

Summary of Contents for TT007

Page 1: ...s Consoles Operation Manual Document Revision 2 0 Release Date February 2002 TT007 Version 4 Part Number 840 05044 03 Euphonix Inc 220 Portage Ave Palo Alto California 94306 Phone 650 855 0400 Fax 650...

Page 2: ...t notice or obligation System 5 S 5 PatchNet eMix EuCon R 1 Audio Deck Studio Hub are trademarks of Euphonix Inc 2001 Euphonix Inc All rights reserved worldwide No part of this publication may be repr...

Page 3: ...Lynx Network Support 14 2 1 3 Connecting Controllers to the TT007 15 2 2 Sync Mode Menu 16 2 3 Utility Mode Menu 17 2 4 Presets Mode Menu 19 2 5 Transport Mode Menu 21 Chapter 3 Configurations 23 3 1...

Page 4: ...ices Controllers and Emulators 31 A 3 MIDI Operation with Pro Tools 34 A 3 1 OMS MIDI Setup 34 A 3 2 Pro Tools as Master 35 A 3 3 Pro Tools as Controller 36 A 4 9 Pin Operation with ProTools 37 A 4 1...

Page 5: ...d to Euphonix console 25 3 5 Euphonix console slaved to video machine 25 3 6 Euphonix console slaved in a large network 26 3 7 TcR as Master 27 3 8 LynxNet as Master 28 A 1 TT007 as controller 31 A 2...

Page 6: ...Euphonix TT007 Operation Manual vi List of Tables 2 1 Port Modes 12 2 2 Sync Modes 16 2 3 Function and LCD symbols for front panel keys 21 A 1 Devices and Controllers 31...

Page 7: ...9 pin P2 protocols work right out of the box to insure that starting to work with the TT007 is quick and easy Three MIDI and three serial machine ports are available The TT007 also has a built in time...

Page 8: ...perimposed on a video monitor by simply passing a composite video signal through the TT007 video reference input The TT007 stores 50 user defined presets that are instantly recalled when needed The pr...

Page 9: ...e displayed Port From the Port Assignments Display press the Enter key to select the Menu mode Figure 1 3 TT007 Menu Modes The PREV and NEXT keys scroll through the list of menus Press ENTER to confir...

Page 10: ......

Page 11: ...r more information Slave Port passes only synchronization data timecode to the connected device Master Sets port as the master synchronization source for the entire system Any timecode sync source fro...

Page 12: ...er or Slave Record OFF Safe Recording disabled EDIT Insert recording over audio tracks only ASSEMBLE Overwrite sync track video and audio tracks Track Arm OFF No Track Arming Request is translated to...

Page 13: ...Hard Disk V1 etc Slow Vari Tape DAxx DA88 DA98 etc Tape 33xx 324 3348 3348HR etc Selecting the proper machine type for each serial Slave port provides a fast and reliable lock between device machines...

Page 14: ...eys or the Data Wheel then press the S1 Port key a second time to enter the TimeLine Network configuration menu A master machine must be selected from one of the eight displayed addresses Additional m...

Page 15: ...so they can be cabled directly to devices When connecting an additional controller to the network the transmit Tx and receive Rx pins of the RS 422 interconnect cable must be reversed to enable the TT...

Page 16: ...he setting Table 2 2 Sync Modes Parameter Value Description LCD Symbol Resolve Free Run Internal Clock Reference Video Sync to External Video Reference R TC Detect ON TT007 automatically selects the f...

Page 17: ...rc Selects Port for on screen display Column 0 219 Moves burn in from left to right on screen Line 0 139 Moves burn in up and down on screen Size Mode OFF 1 8 Selects display format for burn in Bottom...

Page 18: ...faster the machine will scan in threaded wind mode This setting is stored with the Preset If set OFF FF and Rew commands are always unthreaded If set to any non zero value the first press of a FF or...

Page 19: ...ta Wheel to select the desired preset by name or preset number Confirm the selection and recall the preset with the ENTER key SHORTCUT Use the Port keys as a fast way to access presets From the Recall...

Page 20: ...called from the console to control the entire net work a group or individual machines NOTE Turning on MSTR CTRL recalls the current preset number lit on the DSC Any TT007 configuration not saved to a...

Page 21: ...ine in the network can be controlled from the TT007 s front panel To access the Transport Mode from the Port Assignments Display 1 Press any Menu key 2 Scroll through the list with the PREV and NEXT k...

Page 22: ......

Page 23: ...soles are designed to control the TT007 as a seamless extension of the Euphonix system All TT007 functionality is available to the mixer as if it were actually embedded in the console In such a situat...

Page 24: ...TC which allows MTC machines to follow SMPTE EBU synchronization networks Figure 3 3 shows how to slave an Audio Workstation on the M1 port to the Euphonix System Figure 3 3 Audio Workstation slaved t...

Page 25: ...configures the S1 Port as Master Figure 3 5 Figure 3 5 Euphonix console slaved to video machine DSC MstrCtrl On TC Slave Off Machine Select 4 S1s S2 S3 ViR 30 S S1 00 18 01 06 M1s M2c M3 TR TGM P 04 M...

Page 26: ...nd remote punch ins 3 2 2 Large Network Serial MIDI LTC Figure 3 6 shows a typical large scale installation that demonstrates the power of a Euphonix studio Figure 3 6 Euphonix console slaved in a lar...

Page 27: ...ster machine via the 9 pin connection and the synchronization timecode is then sent back from the TcR Port This configuration is also useful when regenerated offset code is desired as the synchronizat...

Page 28: ...the entire TT007 We recommend that the master Lynx module feed timecode to the TcR Port using the From Master option to ensure accurate synchronization if video is not present Figure 3 8 LynxNet as Ma...

Page 29: ...ly exclusive i e the TT007 can only use one of them as a reference When either is selected the other automatically toggles OFF Why does the TC reader keep shutting off See above What is the difference...

Page 30: ...TT007 These synchronizers are not yet supported How can I adjust the LCD viewing angle contrast on my display There is no software based control for this feature There is an adjustment potentiometer...

Page 31: ...us TT007 configurations and the cabling required Table A 1 Devices and Controllers TT007 as Controller Figure A 1 shows an example of typical single machine remote control from TT007 using normal Tx R...

Page 32: ...Controller Figure A 3 shows an expanded control configuration that allows two Controllers simul taneous control of a single Device uses reverse Tx Rx cable pinout wiring Figure A 3 TT007 as secondary...

Page 33: ...ny one of the four controllers in the network can operate the transport on the tape machine Uses reverse Tx Rx cable pinout wiring Figure A 4 TT007 as multiple controller hub For additional system con...

Page 34: ...Manual Appendix 34 A 3 MIDI Operation with Pro Tools A 3 1 OMS MIDI Setup Configure settings according to those set in the following dialogs Figure A 5 OMS MIDI Setup Figure A 6 OMS Studio Setup and...

Page 35: ...cording to Figure A 7 Figure A 7 Synchronization tab in the Pro Tools Peripherals dialog On the TT007 set the MIDI port to MTC only and Master This setup will not permit track arming from the console...

Page 36: ...the MIDI Controllers tab configure the settings as shown in Figure A 8 Figure A 8 MIDI Controllers tab in the Pro Tools Peripherals dialog In the Transport Control set the Transport menu to Pro Tools...

Page 37: ...the Pro Tools Peripherals dialog 2 Click the clock on the upper left of the Transport Control so it highlights as shown in Figure A 9 This sets Pro Tools Online and relinquishes local control 3 Select...

Page 38: ...p Arming On or 48 no tallies Use the Pro Tools remote mode 9 pin cable shown below A serial control 9 pin cable or v LAN configuration will not work Figure A 11 Pro Tools Remote Mode 9 pin cable 1 2 3...

Page 39: ...If the tape was striped to a video reference the machine type can be set to Normal TT007 should be video referenced LTC is not needed Master Video Sync 1 Connect video sync to the 3348 and the TT007 2...

Page 40: ...x 5 For System 5 connect the word clock from the 3348 to the SH612 6 Set the SH612 to Reference Word Clock If record and track arming control is needed when running as a slave set Re direct to the mac...

Page 41: ...2 6 1 9 WAY D MALE TT007 2 Controller to Controller Interface Pinout S1 S2 S3 RX RX TX TX TT007 Controller Diagnostic Port i f 1 2 3 4 5 6 7 8 RJ45 Socket This cable allows for connection to a 5 9 4 8...

Page 42: ......

Reviews: