Operating Instructions Safety Systems
MGB2-I-BP.-… / MGB2-I-BR.-…
8
(translation of the original operating instructions) 2530674-02-03/21
5. General safety precautions
Safety switches fulfill personnel protection functions. Incorrect installation or tampering can lead to fatal injuries to personnel.
Check the safe function of the safeguard and, if necessary, other safety functions particularly
Ì
after any setup work
Ì
after the replacement of a system component relevant for safety
Ì
after an extended period without use
Ì
after every fault
Ì
after any change to the DIP switch settings
Independent of these checks, the safe function of the safeguard should be checked at suitable intervals as part of the
maintenance schedule.
WARNING
Danger to life due to improper installation or due to bypassing (tampering). Safety components fulfill
a personnel protection function.
Ì
Safety components must not be bypassed, turned away, removed or otherwise rendered ineffec-
tive. On this topic pay attention in particular to the measures for reducing the possibility of bypass-
ing according to EN ISO 14119:2013, section 7.
Ì
The switching operation is allowed to be triggered only by the intended handle module MGB2-H…
that is positively fastened to the guard.
Ì
Prevent bypassing by means of replacement actuators (only for multicode evaluation). For this
purpose, restrict access to actuators and to keys for releases, for example.
Ì
Mounting, electrical connection and setup only by authorized personnel possessing the following
knowledge:
-specialist knowledge in handling safety components
-knowledge about the applicable EMC regulations
-knowledge about the applicable regulations on operational safety and accident prevention.
Important!
Prior to use, read the operating instructions and keep these in a safe place. Ensure the operating
instructions are always available during mounting, setup and servicing. For this reason you should
archive a printed copy of the operating instructions. You can download the operating instructions from
www.euchner.com.
6. Function
Together with a handle module, the interlocking module makes it possible to interlock movable guards. The combination
also serves as a mechanical door stop at the same time.
The following switch-on condition applies to the safety outputs FO1A and FO1B (also see chapters
and
14.3. System status table MGB2-BP on page 38
):
Ì
Guard closed
Ì
Bolt tongue inserted into the interlocking module
The interlocking module detects the position of the guard and the position of the bolt tongue. The bolt tongue in the handle
module is moved into and out of the interlocking module by actuating the door handle.