15
2530674-02-03/21 (translation of the original operating instructions)
Operating Instructions Safety Systems
MGB2-I-BP.-… / MGB2-I-BR.-…
EN
8. Mounting
WARNING
Mounting must be performed only by authorized personnel.
NOTICE
Risk of damage to equipment and malfunctions as a result of incorrect installation.
Observe EN ISO 14119:2013, sections 5.2 and 5.3, for information about mounting the safety switch
and the actuator.
With two-leaf hinged doors, one of the two door leaves must also be latched mechanically.
Use a rod latch (Item) or a double-door lock (Bosch Rexroth) for this purpose, for example.
Important!
Ì
In case of flush installation, the operating distances change as a function of the installation depth
and the guard material.
Interlocking
module
Handle module
Interlocking
module
Handle module
Surface mounting
Flush installation
Actuating range
Actuating range
Tip!
Ì
You will find an animation on the mounting process at www.euchner.com.
Ì
The pushbuttons and indicators can be customized using replaceable color covers and labels.
For mounting steps, see
Install system so that inspection and service are possible.