9
119138-05-10/15 (translation of the original operating instructions)
Operating Instructions
Safety Systems with Locking ESL-IH-AR
EN
7. Mounting
CAUTION
Safety systems must not be bypassed (bridging of contacts), turned away, removed or otherwise
rendered ineffective.
Ì
Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by-
passing an interlocking device.
Ì
The device is not suitable for use on sliding doors.
Ì
When mounting, take care not to trap the cables between the device and the profile.
Ì
Permanently connect the interlocking module and handle module to the safety guard so that they
cannot be detached, e.g. using non-removable screws.
NOTICE
Risk of damage to equipment and malfunctions as a result of incorrect installation.
Ì
When mounting several transponder-coded safety switches, observe the stipulated minimum dis-
tance to avoid mutual interference.
min. 60 mm
7.1. Changing the connection
The plug connector position can be adapted to suit the installation. This change must be performed before assembly:
1. Press the plug connector with the plastic inserts out of the profile slot.
¨
To adjust only the cable exit for angled plug connectors, align the plug and the inserts accordingly and press the plug
back into the profile slot.
2. Remove the connection cap on the opposite side.
3. For angled plug connectors, align the plug and the inserts accordingly.
4. Press the plug into the profile slot on the opposite side.
5. Seal the other opening with the connection cap.