![EUCHNER CTP-I.-AS Operating Instructions Manual Download Page 11](http://html.mh-extra.com/html/euchner/ctp-i-as/ctp-i-as_operating-instructions-manual_2434853011.webp)
11
2543028-02-01/21 (Translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CTP-I.-AS
EN
7.3.
Escape release (optional)
Permits opening of a locked guard from the danger zone without tools (see chapter
drawing for safety switch CTP… on page 20
).
Important!
Ì
It must be possible to actuate the escape release manually from in-
side the protected area without tools.
Ì
It must not be possible to reach the escape release from the outside.
Ì
The actuator must not be under tensile stress during manual release.
Ì
The escape release meets the requirements of Category B according
to EN ISO 13849-1:2015.
7.3.1. Actuating escape release
Press the red release knob to the end stop.
¨
Guard locking is released.
Pull the knob out again to reset.
Open the guard and close it again after resetting the escape release. The device will then operate normally again.
7.4.
Wire front release (bowden)
Release via a pull wire. Depending on the type of attachment, the wire front release can be used as a front release or escape
release.
Important!
Ì
The wire front release meets the requirements of Category B accord-
ing to EN ISO 13849-1:2015.
Ì
The correct function depends on the laying of the pull wire and the at-
tachment of the pull handle. The plant manufacturer is responsible for
proper installation; the notes from chapter
must be observed.
Ì
The actuator must not be under tensile stress during manual release.
7.4.1. Laying wire front release
Important!
Ì
Loss of the release function due to mounting errors, damage or wear.
Ì
Check the release function every time after mounting.
Ì
When routing the wire front release, ensure that it operates smoothly.
Ì
Observe the min. bending radius (100 mm) and minimize the number of bends.
Ì
The switch is not allowed to be opened.
Ì
Observe the notes on the enclosed data sheets.