![EUCHNER CTP-I.-AS Operating Instructions Manual Download Page 10](http://html.mh-extra.com/html/euchner/ctp-i-as/ctp-i-as_operating-instructions-manual_2434853010.webp)
Operating Instructions
Transponder-Coded Safety Switch CTP-I.-AS
10
(Translation of the original operating instructions) 2543028-02-01/21
7.1.2. Actuating auxiliary key release
On devices with auxiliary key release (can be retrofitted), simply turn the key to release. Function
as for auxiliary release. For mounting, see the auxiliary key release supplement.
7.2.
Emergency release
Permits opening of a locked guard from outside the danger zone without tools. For mounting,
see the mounting supplement.
Important!
Ì
It must be possible to operate the emergency release manually from outside the protected area
without tools.
Ì
The emergency release must possess a marking indicating that it may be used only in an emergen-
cy.
Ì
The actuator must not be under tensile stress during manual release.
Ì
The emergency release must be sealed or the misuse of the release function must be prevented in
the control system.
Ì
The release function meets all other requirements from EN ISO 14119.
Ì
The emergency release meets the requirements of Category B according to
EN ISO 13849-1:2015.
Ì
Loss of the release function due to mounting errors or damage during mounting.
Ì
Check the release function every time after mounting.
Ì
Please observe the notes on any enclosed data sheets.
7.2.1. Actuating emergency release
Turn emergency release clockwise until it clicks into place.
¨
Guard locking is released.
To reset, press the snap-in bolt inward using a small screwdriver or similar tool and turn the
emergency release back.
Open the guard and close it again after resetting the emergency release. The device will then
operate normally again.
Snap-in bolt