12. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
12.1. Technical data for safety switch CTM-L2-AS1B
Parameter
Value
Unit
min.
typ.
max.
General
Material
- Seals
- Switch housing
Fluorinated rubber (FKM)
Reinforced thermoplastic
Installation orientation
Any
Degree of protection
IP65/IP67/IP69/IP69K
(screwed tight with the related mating connector)
Safety class acc. to EN IEC 61140
III
Degree of contamination (external, acc. to EN 60947-1)
3 (industrial)
Mechanical life
1 x 10
6
operating cycles
Ambient temperature at U
B
= 24 V
-20
-
+60
°C
Actuator approach speed
-
-
20
m/min
Actuating/extraction force
Device dependent, see www.euchner.com
N
Locking force F
max
1,300
N
Locking force F
Zh
1)
F
Zh
= F
max
/1.3 = 1,000
N
Weight
Approx. 0.16
kg
Connection (depending on version)
1 plug connector M12, 4-pin
The following applies to the approval acc. to UL
Operation only with UL class 2 power supply or equivalent measures
Resilience to vibration
Acc. to EN 60947-5-3
EMC protection requirements
Acc. to EN 60947-5-3
Ready delay
-
-
3
s
Risk time
-
-
220
ms
Turn-on time
-
-
400
ms
Solenoid
Auxiliary voltage
24 +10%/-15% (PELV)
V DC
Current consumption with auxiliary voltage
650
mA
Duty cycle
100
%
AS-Interface data
EA code: 7
ID code: B
AS-i operating voltage
26.5
-
31.6
V DC
Total current consumption from AS-i
CTM-..-AS.B
-
-
50
mA
Valid AS-Interface addresses
1 - 31
AS-Interface inputs
Acc. to ASi Safety at Work
Influenced by door position
CTM-..-AS1..
D0, D1
CTM-..-AS2..
D0, D1, D2, D3
Influenced by guard locking
CTM-..-AS1..
D2, D3
CTM-..-AS2..
D0, D1, D2, D3
AS-Interface outputs
Guard locking solenoid
D0 (1 = solenoid energized)
Reliability values acc. to EN ISO 13849-1
Mission time
20
years
Monitoring of guard locking and the guard position
Category
4
Performance Level (PL)
e
PFH
D
1.468 x 10
-8
Control of guard locking
Category
Depends on external control
Performance Level (PL)
PFH
D
1) Dependent on the actuator used