29
2537376-01-04/21 (translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CTP/CTA-L1/2-BR
EN
Connected load
Safety Outputs
Door
Monitoring
Safety Inputs
Monitoring Outputs
Diagnostic
Locking
active
Read Head
Actuator
FI1A
X1:6
FI1B
X1:1
-B1
UB
X1:2
IMP
X2:4
IMM
X2:1
RST
X1:8
0 V
UB
X1:7
OD
X2:2
FO1A
X1:3
FO1B
X1:4
OL
/C
X1:5
NC
X2:5
OI
X2:3
Safety Outputs
Door
Monitoring
Safety Inputs
Monitoring Outputs
Diagnostic
Locking
active
Read Head
Actuator
FI1A
X1:6
FI1B
X1:1
-B2
UB
X1:2
IMP
X2:4
IMM
X2:1
RST
X1:8
0 V
UB
X1:7
OD
X2:2
FO1A
X1:3
FO1B
X1:4
OL
/C
X1:5
NC
X2:5
OI
X2:3
Safety Outputs
Door
Monitoring
Safety Inputs
Monitoring Outputs
Diagnostic
Locking
active
Read Head
Actuator
FI1A
X1:6
FI1B
X1:1
-B3
UB
X1:2
IMP
X2:4
IMM
X2:1
RST
X1:8
0 V
UB
X1:7
OD
X2:2
FO1A
X1:3
FO1B
X1:4
OL
/C
X1:5
NC
X2:5
OI
X2:3
BR Evaluation unit/
IO-Link
13
14
-S1
1
2
-F1
1
2
-F2
1
2
-F3
24V DC
0 V
24V DC
0 V
Figure 5:
Connection example for series connection with wiring in the control cabinet