9. Mounting
CAUTION
Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise
rendered ineffective.
Ì
Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by-
passing an interlocking device.
Ì
The max. achievable category according to EN 13849-1 depends on the installation position (see
chapter
13. Technical data on page 27
).
NOTICE
Risk of damage to equipment and malfunctions as a result of incorrect installation.
Ì
Safety switches and actuators must not be used as an end stop.
Ì
Observe EN ISO 14119:2013, sections 5.2 and 5.3, for information about fastening the safety
switch and the actuator.
Ì
Protect the switch head against damage, as well as penetrating foreign objects such as swarf,
sand and blasting shot, etc. The switch should be installed with the actuating head down for this
purpose.
Ì
Observe the min. door radii (see figure below).
Ì
Ensure that the actuator contacts the ramp in the designated area (see figure below). Marks on the
ramp specify the prescribed approach zone.
Tip!
EUCHNER offers special cover plates to improve protection against tampering. These accessories
can be found at www.euchner.com.
min
R=
300
min
R=1
000
min R800
Figure 2:
Door radii and approach zone