23
112663-05-03/15 (translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-AP-C01-…
EN
6.3. Technical data of actuator CES-A-BPA
Parameter
Value
Unit
min.
typ.
max.
Housing material
PBT
Dimensions
40 x 40 x 10
mm
Ground
0.025
kg
Ambient temperature
- 25
-
+ 70
°C
Degree of protection acc. to EN IEC 60529
IP67/IP69K
Installation position
Active face opposite read head
Power supply
Inductive via read head
6.3.1. Dimension drawing
30
±0,1
40
- 0,25
0
CES-A-BPA-098775
IP67
CD
10
4
Ø
5,2
Active face
Active face
NOTICE
2 safety screws M5 x 10 included.
6.3.2. Operating distances
Operating distance for center offset m = 0
Parameter
Value
Unit
min.
typ.
max.
Switch-on distance
-
22
1)
-
mm
Assured switch-on distance s
ao
18
-
-
Switching hysteresis
1
2
-
Assured switch-off distance s
ar
-
-
58
1) On surface mounting on aluminum; in a non-metallic environment the typical switching distance increases to 30 mm.