![EUCHNER CES-AP-C01- Series Operating Instructions Manual Download Page 19](http://html.mh-extra.com/html/euchner/ces-ap-c01-series/ces-ap-c01-series_operating-instructions-manual_2434829019.webp)
19
112663-05-03/15 (translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-AP-C01-…
EN
6. Technical data
NOTICE
If a product data sheet is included with the product, the information on the data sheet applies.
6.1. Technical data of safety switch CES-AP-C01-…
Parameter
Value
Unit
min.
typ.
max.
Housing material
Plastic PBT
Dimensions
According to EN 60947-5-2
Weight
0.4
kg
Ambient temperature at U
B
= DC 24 V
- 20
-
+ 55
°C
Storage temperature
- 25
-
+ 70
Degree of protection acc. to EN IEC 60529
IP 67
Safety class
III
Degree of contamination
3
Installation position
Any
Connection
M12 plug connector, 5-pin or 8-pin
Operating voltage U
B
(regulated, residual ripple < 5%)
24 ± 15% (PELV)
V DC
Current consumption
50
mA
External fuse
(operating voltage)
0.25
-
8
A
Safety outputs OA/OB
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U(OA)/U(OB)
1)
HIGH
U(OA)
U
B
-1.5
-
U
B
V DC
HIGH
U(OB)
LOW
U(OA)/U(OB)
0
1
Switching current per safety output
1
-
400
mA
Utilization category according to EN IEC 60947-5-2
DC-13 24 V 400 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.
Off-state current I
r
2)
≤ 0.25
mA
Monitoring output DIA
1)
p-switching, short circuit-proof
- Output voltage
0.8 x U
B
-
U
B
V DC
- Max. load
-
-
200
mA
Rated insulation voltage U
i
-
-
300
3)
V
Rated impulse withstand voltage U
imp
-
-
1.5
kV
Resilience to vibration
In acc. with EN IEC 60947-5-2
Switching frequency
-
-
1
Hz
Repeat accuracy R
acc. to EN IEC 60947-5-2
≤
10
%
EMC protection requirements
In accordance with EN IEC 60947-5-3 and EN IEC 61326-3-1
Ready delay
-
0.5
-
s
Risk time
-
-
260
ms
Switch-on time
-
-
400
ms
Discrepancy time
-
-
10
ms
Test-pulse duration
400
µs
Reliability values according to EN ISO 13849-1
Category
4
Performance Level
PL e
PFH
d
2.1 x 10
-9
/ h
Mission time
20
years
1) Values at a switching current of 50 mA without taking into account the cable length.
2) Maximum current at an output in switched-off state.
3) Tested by employers’ liability insurance association up to 75 V.