11.3. Read head CES-A-LNA-SC
Ì
Cube-shaped design 42 x 25 mm
Ì
M8 plug connector (snap-action and screw terminals)
Dimension drawing
5,5
∅
10
6,8
∅
8
∅
4,
5
4,6
12
25
min.38
32 ±0,1
42
32,6
A0
CES-A-L 077715
3
4
1
A0
CES-A-L 077715
20 1
,
26
,5
2 safety screws M4 X 14
included
Cable outlet with angled
connector
Active face
Active face
Typical operating distance
With evaluation unit CES-A-ABA-… and actuator CES-A-BBA
-8
-4
-6
-2
2
6
4
8
0
2
4
6
8
Centre offset m [mm]
Distance s [mm]
OFF
ON
Actuator
Read head
s
m
Hysteresis
Switch-on
distance
ON
OFF
Hysteresis
Distance s
S
ao
Output stage
Switch-off
distance
OFF
Approvals