21
2527246-01-08/19 (Translation of the original operating instructions)
Operating Instructions
Safety System MGBS-P-L.-AR…
EN
10. Mounting
CAUTION
Locking modules must not be bypassed (bridging of contacts), turned away, removed or otherwise
rendered ineffective.
Ì
Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by-
passing an interlocking device.
NOTICE
Risk of damage to equipment and malfunctions as a result of incorrect installation.
Ì
Locking modules and handle module must not be used as an end stop.
Ì
Observe EN ISO 14119:2013, sections 5.2 and 5.3, for information about mounting the locking
module and the handle module.
Ì
Protect the switch head against damage, as well as penetrating foreign objects such as swarf,
sand and blasting shot, etc.
Ì
Observe the min. door radii (see chapter
7.4. Dimension drawing (example illustration) on page 12
).
Ì
Observe the tightening torque for fastening the locking module (max.1.4 Nm)
10.1. Mounting examples
6 Nm
1 Nm
Figure 2:
Mounting without escape release and without inner door handle
6 Nm
6 Nm
1 Nm
Figure 3:
Mounting with escape release and inner door handle