Operating Instructions
Non-Contact Safety Switch CES-I-BR-.-C07-…
28
(translation of the original operating instructions) 2510145-05-08/21
Reliability values acc. to EN ISO 13849-1:2015
Category
4
Performance Level
PL e
PFH
D
6 x 10
-10
/ h
Mission time
20
years
Reliability values acc. to EN 62061:2005/A2:2015
SILCL3
1) Values at a switching current of 50 mA without taking into account the cable lengths.
2) The reaction time is the time until the moment when at least one of the outputs (FO1A or FO1B) switches off when the actuator is removed from the actuating range, given compliance with all manufac-
turer’s specifications.