Installation:
•
Choose a suitable installation place for the smoke detector. If mounted on the ceiling in the centre of
the room assures an optimal performance of the smoke detector.
•
Keep a distance of at least 15 cm from each wall and at least 65 cm from each corner.
•
Avoid places with increased dust, gas or dirt load because they can cause false alarms (i.e. kitchen).
•
Use the screw holes of the mounting plate as drill template.
•
Bore the holes with a 5 mm drill and insert the wall plugs.
•
Fasten the mounting plate to the ceiling.
•
For energizing the smoke detector insert a 9 V-battery. Now the red LED (2) should flash every 40
seconds.
•
Hold the smoke detector to the bracket and turn it clockwise to fasten it.
•
Press the test button until the audio warning sounds and both LEDs flash in a high frequency.
•
If the 9 V-battery is getting weak the smoke detector shows by irregular flashing of the LED and an
audio warning every minute.
Usage of more than one Smoke Detector (Training):
•
Press 2x LEARN of the first smoke detector. This device will be the MASTER while all following will be
SLAVES. During the training the LED (3) of the MASTER must show green always.
•
Press 2x LEARN on all following detectors. If the slaves were trained successfully the LED (3) of each
shows red.
•
After all SLAVES are connected to the MASTER press the MASTER’S test button. Now all devices of the
system give an acoustic signal.
•
Now press TEST of any smoke detector of the system. All smoke detectors will sound an alarm now. The
LED (3) of the operated device will show red while all others show green.
Recommandations:
•
Install one smoke detector each room if possible.
•
Keep the louvers free from dust and dirt.
•
Perform functional tests in regular intervals.
•
Make sure the battery is not too weak.
•
Exchange each smoke detector every 5 years for safety reasons.
In case of alarm leave the building as fast as possible and call the fire fighters from outside. Do not
open doors if smoke is pouring out and never open windows if they are not your exit!