GROUNDING THE GENERATOR
The National Electric Code requires that the
frame of generator and the external electrically
conductive parts of the generator be connected
to an approved earth ground. Local codes may
differ and require other grounding specifications.
For this purpose, please use the ground wire
that attaches from the frame to the generator
unit.
Using a No. 12 AWG (American Wire Gauge)
stranded copper wire to the frame and to an
earth-driven copper or brass grounding rod
provides sufficient safety against shock.
However, local codes may differ. Contact a local
electrician to find out specifications for
grounding your generator.
Note: Grounding your generator is highly
recommended. It helps prevent electrical shock
if a ground fault condition exists in the generator
or in faulty connected electrical devices. Also,
because the generator is rotating at high speeds,
static electricity tends to buildup within the unit.
Grounding helps dissipate the static electricity
buildup often buildup in underground devices.
OPERATING THE GENERATOR
STARTING THE ENGINE
Before starting the engine, verify that the engine
oil is full, gasoline is full, and air Filter is in place.
Also, disconnect any load from the AC
receptacle
(Figure 1) .
Figure 1. Disconnecting electrical devices
•
Turn the fuel valve to the "On" position
(Figure 2).
Figure 2. Fuel Valve
Figure 3. Engine switch on position