26
3-2 Storing for long periods of time
If your generator needs to be stored for long periods of time, the following preparations
should be made.
1. Start the diesel engine for 3 minutes then stop it.
2. When the engine is still hot, change the engine oil with new engine oil of the
proper grade.
3. Pull the rubber plug out of the cylinder head cover and put 2CC of lubricating oil
in it, then cover the plughole up again.
4. For manual starting generator welders, press the decompression handle down and
pull the recoil handle 2 or 3 times. This pushes the intake out. (Do not start the
engine)
5. For electric started generator welders, press the decompression handle down and
crank the engine for 2-3 seconds. To do this, put the starter switch in the “Start”
position. (Do not start the diesel engine)
6. Finally, pull the recoil starter until you feel resistance; this is when the piston is
on the compression stroke where the intake and exhaust valves are closed.
Having the intake and exhaust valves closed will prevent rust, as moisture cannot
get inside the combustion chamber.
7. Clean the engine and store it in a dry place.