Etnyre Centennial Manual Download Page 5

5

ON

OFF

LATCH

UNLATCH

0

F PM

0

0

1

GPM

0 . 000

G/SQYD

F T - I N

0 - 0

Cab Control Panel

Rear Control Panel

1

2

6

3

4

2

3

5

1. SPRAY Switch

Turning this switch to ON when the
Function knob (rear panel) is turned
to BAR CIRCULATE or BAR SUCK
BACK, opens all activated spray
valves.

2. START Button

Starts the asphalt pump turning at the
target pump rate or starts calibration
operations in the setup screens.

3. POWER Switch

Both POWER switches, front and
rear, must be ON for the system to
be ON. The entire system can be shut
down by turning either POWER
switch to OFF. Before turning either
POWER switch to ON be sure you
know what will automatically activate.

4. PUMP SPEED Control Knob

When MANUAL PUMP CONTROL is
selected, turning this knob to the right
(clockwise) increases the asphalt
pump speed. It is possible to over-
speed the asphalt pump in MANUAL
control since the asphalt pump speed
is also dependent on the engine
speed.

Always turn the knob back to the left
(counter-clockwise) before selecting
AUTO PUMP CONTROL or turning
ON either POWER switches (front or
rear).

5. Function knob

When the desired operation is se-
lected through this knob, the asphalt
pump stops turning if the PUMP CON-
TROL is in AUTO, and all automatic
valves (tank valve, 4-way valve, bar
suck back valves, and balance valves)
are set for the desired operation. The
asphalt pump rate is set to the stored
preset for the desired operation.
The factory pump rate presets are:
• LOAD/TRANSFER - 100 GPM
• TANK CIRCULATE - 150 GPM
• BAR SUCK BACK - 200 GPM
• BAR FLUSH - 100 GPM
• UNLOAD - 100 GPM
• HAND SPRAY - 50 GPM
When BAR CIRCULATE is selected,
the asphalt pump rate is calculated
based on the displayed spray width,
application rate, and the setting of the
%CIRC factor.

6. PUMP CONTROL Switch

With the switch turned to AUTO, the
asphalt pump speed is controlled at
the desired rate through the computer.

With the switch turned to MANUAL,
the asphalt pump speed is controlled
with the PUMP SPEED control knob
at the desired rate for a specific en-
gine speed.

Control Panels

Summary of Contents for Centennial

Page 1: ...33 S Daysville Road Oregon Illinois 61061 Phone 815 732 2116 Fax Sales 815 732 7400 email sales etnyre com www etnyre com Centennial Flow Charts and Control Positions A 130 08 Variable Width Spraybar with BT 1 Controls ...

Page 2: ...2 ...

Page 3: ...ity to read and understand the instructions should be a required qualification to become an operator There are also functions that require a certain amount of physical strength to accomplish Persons lacking the required strength may not only place themselves in jeopardy but also others in the vicinity Read and understand the Safety precautions found in M 114 08 Centennial Asphalt Distributor Opera...

Page 4: ...n the BAR SUCK BACK OVERRIDE switch ON 2 Press START The pump will start turning at the desired rate 200 GPM is recommended 3 If complete bar suck back is desired follow the instructions for bar suck back beginning with the opening of the left bleeder valve Otherwise continue to the next step 4 Turn the BAR SUCK BACK OVERRIDE switch OFF 5 Press START The pump will start turning at the desired circ...

Page 5: ...the engine speed Always turn the knob back to the left counter clockwise before selecting AUTO PUMP CONTROL or turning ON either POWER switches front or rear 5 Function knob When the desired operation is se lected through this knob the asphalt pump stops turning if the PUMP CON TROL is in AUTO and all automatic valves tank valve 4 way valve bar suck back valves and balance valves are set for the d...

Page 6: ...d Flush Valve Closed 4 Way Valve Circulate in Tank Return Valve Closed Cab Panel POWER Switch OFF Rear Panel Function Switch to LOAD TRANSFER position POWER Switch OFF The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions 0 FPM 0 0 0 GPM 0 000 G SQYD F T I N 0 0 ON OFF LATCH UNLATCH Load through Ma...

Page 7: ...lve Open The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions 0 FPM 0 0 1 GPM 0 000 G SQYD F T I N 0 0 ON OFF LATCH UNLATCH Cab Panel POWER Switch ON 100 GPM adjust using VALUE switch Rear Panel PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to LOAD TRANSFER p...

Page 8: ...ar Panel PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to TANK CIRCULATE position POWER Switch ON Push START switch The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions 0 FPM 0 0 1 GPM 0 000 G SQYD F T I N 0 0 ON OFF LATCH UNLATCH Cab Panel POWER Switch ON Pu...

Page 9: ...MP SPEED knob zero fully counterclockwise Function Switch to BAR CIRCULATE position POWER switch ON Push START switch The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions 0 FPM 0 0 1 GPM 0 000 G SQYD F T I N 0 0 ON OFF LATCH UNLATCH Cab Panel POWER switch ON SPRAY switch OFF Set the application ra...

Page 10: ...alve Open Rear Panel Function Switch to BAR CIRCULATE position The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions 0 0 3 FPM 0 8 1 GPM 0 300 G SQYD F T I N 8 1 0 ON OFF LATCH UNLATCH Cab Panel Spraybar Switches as desired ON When the spray bar reaches the beginning of the shot turn the SPRAY swit...

Page 11: ...TROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to BAR SUCK BACK position POWER switch ON Push START switch The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions 0 0 0 FPM 0 0 2 GPM 0 300 G SQYD F T I N 0 0 ON OFF LATCH UNLATCH Suckback Spraybar Open bleeder valve at th...

Page 12: ...e pressure is desired increase GPM before Return Valve is completely closed Cab Panel POWER switch ON 50 GPM adjust using VALUE switch Rear Panel PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to HANDSPRAY position POWER switch ON Push START switch The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial O...

Page 13: ...switch The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions 0 0 0 FPM 0 0 2 GPM 0 300 G SQYD F T I N 0 0 ON OFF LATCH UNLATCH Hand Spray Valve Open Tank Valve Closed Suck Back Valve Open Master Handspray Valve Suckback Transfer Valve Closed Transfer Line Suck Back Valve Closed Flush Valve Closed 4...

Page 14: ...ions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions 0 FPM 0 0 1 GPM 0 000 G SQYD F T I N 0 0 ON OFF LATCH UNLATCH Hand Spray Valve Closed Tank Valve Open Suck Back Valve Closed Master Handspray Valve Off Transfer Valve Open Transfer Line Suck Back Valve Closed Flush Valve Closed 4 Way Valve Circulate in Tank...

Page 15: ...nel POWER Switch ON 100 GPM adjust using VALUE switch Rear Panel PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to LOAD TRANSFER position POWER Switch ON Push START switch The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions 0 FPM 0 0 1 GPM 0 000 G SQYD F T I ...

Page 16: ... Rear Panel PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to LOAD TRANSFER position POWER Switch ON Push START switch WASH PUMP switch optional ON The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions 0 FPM 0 0 1 GPM 0 000 G SQYD F T I N 0 0 ON OFF LATCH UNLAT...

Page 17: ... Cab Panel POWER Switch ON 100 GPM adjust using VALUE switch Rear Panel PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to BAR FLUSH position POWER Switch ON Push START switch WASH PUMP Switch optional ON The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions 0 F...

Page 18: ... Panel POWER Switch ON 100 GPM adjust using VALUE switch Rear Panel PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to LOAD TRANSFER position POWER Switch ON Push START switch FRONT LOAD switch optional OPEN The instructions represented here are a guide and not designed to be comprehensive Refer to M 114 08 Centennial Operation Manual for complete instructions ...

Page 19: ... 58 4 0 to 7 5 3 3351009 S36 5 V Slot 18 45 81 2 04 7 0 to 10 0 4 3352368 Multi Material V Slot 15 40 68 1 81 6 0 to 9 0 5 3351015 3 32 Coin Slot 15 40 68 1 81 6 0 to 9 0 6 3352204 Multi Material V Slot 35 95 1 58 4 30 12 0 to 21 0 7 3352205 Multi Material V Slot 20 55 91 2 49 7 5 to 12 0 8 3352210 End Nozzle 3352205 20 55 91 2 49 7 5 to 12 0 9 3351014 3 16 Coin Slot 35 95 1 58 4 30 12 0 to 21 0 1...