11
Suck
Back
Off
Hand
Spray
Hand Spray Valve Positions
Tank Valve
Closed
Suck Back Valve
Open
Master
Handspray
Valve
Off
Transfer Valve Closed
Hand Spray
Valve
Closed
Transfer Line
Suck Back
Valve
Closed
Flush Valve
Closed
4 Way Valve
Circulate in Tank
Return Valve
Open
Bleeder
Valve
Cab Panel
• POWER switch ON
• 200 GPM - adjust using VALUE switch
Rear Panel
• PUMP CONTROL switch AUTO
• PUMP SPEED knob zero (fully counterclockwise)
• Function Switch to BAR SUCK BACK position
• POWER switch ON
• Push START switch
The instructions represented here
are a guide and not designed to be
comprehensive. Refer to M-114-08
Centennial Operation Manual for
complete instructions.
0
0
0
F PM
0
0
2
GPM
0 . 3 00
G/SQYD
F T - I N
0 - 0
ON
OFF
LATCH
UNLATCH
Suckback
Spraybar
Open bleeder valve at the end of one of the wings. Leave it
open until you hear a positive indication of vacuum at the
valve. After closing the valve, repeat the procedure on the
opposite wing.