15
Suck
Back
Off
Hand
Spray
Hand Spray Valve Positions
Tank Valve
Closed
Master
Handspray
Valve
Off
Transfer
Valve
Open
Hand Spray
Valve
Closed
Transfer Line
Suck Back
Valve
Closed
Flush Valve
Closed
4 Way Valve
Circulate in Tank
Return Valve
Closed
Cab Panel
• POWER Switch ON
• 100 GPM - adjust using
VALUE switch
Rear Panel
• PUMP CONTROL switch AUTO
• PUMP SPEED knob zero (fully counterclockwise)
• Function Switch to LOAD/TRANSFER position
• POWER Switch ON
• Push START switch
The instructions represented here are a guide
and not designed to be comprehensive. Refer
to M-114-08 Centennial Operation Manual for
complete instructions.
0
F PM
0
0
1
GPM
0 . 000
G/SQYD
F T - I N
0 - 0
ON
OFF
LATCH
UNLATCH
Suck Back Valve
Closed
Transfer
Summary of Contents for Centennial