Installation and connection
Selecting the location
•
Place the appliance in a dry and well aired room. The permitted
ambient temperature range for the appliance depends on the
appliance's climate class, which is shown on the type plate.
•
Do not place the appliance near a source of heat, such as a gas cooker, radiator or boiler, etc.,
and do not expose it to direct sunlight.
Relative humidity
Ambient temperature range °C
Class
Description
≤75%
+10 to +32
SN
Extended temperate
+16 to +32
N
Temperate
+16 to +38
ST
Subtropical
+16 to +43
T
Tropical
WARNING!
Do not place the appliance in a room where the temperature can fall below the lowest permitted
ambient temperature: the appliance may not work properly!
WARNING!
Do not place the appliance in a room where the temperature can fall below 5 °C: the appliance
may not work properly or become defective!
WARNING!
The appliance is not suitable for outdoor use and it may not be exposed to rain.
•
The appliance must be placed at a distance of at least 5 cm from an electrical or gas cooker and
at least 30 cm from a radiator or heater. An insulation panel must be fitted when these distances
cannot be kept.
•
The appliance must be placed at a distance of about 5 cm from the wall, back and sides of a
cupboard. A kitchen cupboard above the refrigerator must have a gap of at least 5 cm between
the back of the cupboard and the wall. This is needed to make sure that there is sufficient cooling
air for the condenser.
•
The plug of the installed appliance must remain accessible!
WARNING!
Place the appliance in a room with a sufficient volume of air. The room must have a volume of
at least 1 m
3
of air for every 8 grams of refrigerant. The quantity of refrigerant is shown on the
type plate on the inside of the appliance.
13
Summary of Contents for KVV793 Series
Page 1: ...KVV793...
Page 3: ...30 Storingstabel 33 Milieuaspecten 33 Verpakking en apparaat afvoeren 3...
Page 35: ...KVV793...
Page 69: ...KVV793...
Page 71: ...31 Fehlermeldungen 34 Umweltschutz 34 Entsorgung von Ger t und Verpackung 3...
Page 104: ...KVV793...
Page 106: ...30 Faults table 33 Environmental aspects 33 Disposal of packaging and appliance 3...