Operating Mode
Description
LCD Display
ECO Mode
When the input voltage is within voltage regulated
range, UPS will power the output directly from the
mains. ECO is an abbreviation of Efficiency Corrective
Optimizer. In this mode, when the battery is fully
charged, the fan will stop working to save energy
Buck Mode when
AC is normal
When the input voltage is higher than the voltage
regulation range but lower than high loss point, the
buck AVR will be activated
Boost mode when
AC is normal
When the input voltage is lower than the voltage
regulation range but higher than low loss point, the
boost AVR will be deactivated
Battery Mode
When the input voltage is beyond the acceptable range
or power failure and alarm is sounding every 10 seconds,
UPS will backup power from battery
Standby Mode
UPS is powered off and no output supply power, but can
still charge batteries
Fault Mode
When a fault occurs, the ERROR icon and the fault code
will be displayed
2.6 Operating Mode Description
Fault Event
Fault Code
Icon
Bus start fail
01
x
Bus over
02
x
Bus Under
03
x
Inverter soft start fail
11
x
Inverter voltage high
12
x
Inverter voltage low
13
x
Fault Event
Fault Code
Icon
Inverter output short
14
x
Battery voltage too high
27
x
Battery voltage too low
28
x
Over temperature
41
x
Over load
43
Charger failure
13
x
2.7 Faults Reference Codes
Warning
Icon (Flashing
Code
Alarm
Low battery
Sounds every 2 seconds
Overload
Sounds every second
Battery is not connected
Sounds every 2 seconds
Over Charge
Sounds every 2 seconds
Site wiring fault
Sounds every 2 seconds
2.8 Warning Indicator
Warning
Icon (Flashing
Code
Alarm
EPO Enabled
Sounds every 2 seconds
Over temperature
Sounds every 2 seconds
Charger Failure
Sounds every 2 seconds
Battery fault
Sounds every 2 seconds
(UPS will turn off )
Battery replacement
Sounds every 2 seconds
EEPROM error
Sounds every 2 seconds
Note
: “Site Wiring Fault” function can be enabled/disabled via software. Please check soft-
ware manual for the details.
Problems
Cause
Solution
No indication and alarm even though
the mains are normal
The AC input power is not
connected
Check if input power cord firmly connected to
the mains
The AC input is connected to the
UPS output
Plug AC input power cord to AC input correctly
The icon
and the warning code
flashing on LCD display and alarm
is sounding every 2 seconds
EPO function is activated
Set the circuit in closed position to disable EPO
function.
The icon
,
and the warning
code
flashing on LCD display and
alarm is sounding every 2 seconds
Line and neutral conductors of UPS
input are reversed
Rotate main power socket by 180° and then
connect to UPS system
The icon
,
and the warning
code
flashing on LCD display and
alarm is sounding every 2 seconds
The external or internal battery is
incorrectly connected
Check if all batteries are connected
Fault code is shown as 27 on LCD
display and alarm is continuously
sounding
Battery voltage is too high or the
charger is faulty
Contact your dealer
Fault code is shown as 28 on LCD
display and alarm is continuously
sounding
Battery voltage is too low or the
charger is faulty
Contact your dealer
The icon
,
and the warning
code
flashing on LCD display and
alarm is sounding every second
UPS is overloaded
Remove excess loads from UPS output and
restart
Fault code is show as 43 and the icon
is lit on LCD display. Alarm sounds
continuously
The UPS automatically shut down
due to an overload at the output
Remove excess loads from the UPS output and
restart
Fault code is shown as 14 and alarm
sounds continuously
The UPS automatically shut down
because of a short circuit on the UPS
Check output wiring and if connected devices
are in short circuit status
Fault code is shown as 01, 02, 03, 11,
12, 13 and 41 on LCD display and alarm
is continuously sounding
A UPS internal fault has occurred
Contact your dealer
Battery backup time is shorter than
nominal value
Batteries are not fully charged
Charge the batteries for at least 5 hours and
then check capacity. If the problem persists,
consult your dealer
Batteries are defective
Contact your dealer to replace the batteries
Fault code is show as 45 on LCD display
and code is continuously sounding
The charger does not have output
and battery voltage is less than
10V/PC
Contact your dealer