Mounting
Fix the bracket on the wall with screws and attach
the detector to the bracket. We recommend to
mount the detector at a height of 2.2m.
The detector is more sensitive to horizontal
movements than vertical movements, and does
not detect animals under 25 kg.
Avoid mounting the detector close to windows,
air conditioner, heater, refrigerator, oven,
sunshine and places where the temperature
changes fast or where the air stream flows
frequently.
2.2m
<25kg
Important: understanding the standby mode
If the detector is triggered more than twice within 3 minutes, it switches to
standby mode to save power. During standby mode, the detector is inactive.
If within the next 3 mintutes a new movement is detected, the standby
mode is extended by 3 minutes. If no movement is detected within the next
3 minutes, the sensor is activated again.
Testing
After the installation, turn the detector on. After one minute of self-testing, press
the test button, walk in the scope of detection and watch the LED indicator to
make sure the detector is working.