background image

www.etiger.com

Secual Box

User manual

Summary of Contents for secual box

Page 1: ...www etiger com Secual Box User manual ...

Page 2: ...ifications 10 Using the app without Wi Fi connection 11 Daily use Arm the system 13 Arm in Home mode 13 Disarm the system 14 SOS function 14 Control by phone call 15 Check system status 16 If your alarm is triggered 17 Settings How to modify the settings of your Secual Box 19 By app Secual Box connected to Wi Fi 19 By SMS with a SIM card in the control panel 19 Save SMS numbers 20 Save phone numbe...

Page 3: ...unting 34 Testing 34 LED indications 35 Connection to your alarm system 35 Specifications 35 Door Window contact ES D3C 36 Design 36 Mounting 36 Connection to your alarm system 36 Specifications 37 Remote control ES RC1 38 Design 38 Connection to your alarm system 38 Specifications 38 Connect additional accessories 40 Connect additional detectors controls 40 Connect additional sirens 40 Precaution...

Page 4: ... x1 Screws and anchors Documentation Design SIM 2 SIM card slot 4 Power switch 3 Connection button 5 Power adapter input 1 SOS button LED indications Top Blue fixed system armed Blinking blue Home mode Blinking slowly white connected to GSM signal Blinking rapidly white not connected to GSM signal Bottom Green fixed powered and switched on Blinking green powered on on batteries Blinking blue Wi Fi...

Page 5: ...s with secure connection Can store up to 5 phone numbers 5 SMS numbers SIM card required for communication by SMS and phone call Built in 95 dB siren and backup batteries lithium 7 4V 500mAh up to 8 hours in standby mode Specifications Product name Secual Box SKU ESB WS1A Control panel power supply Input AC 110 240V 50 60 Hz Output DC 12V 1A Wi Fi 802 11b g n GSM frequency 850 900 1800 1900 MHz Ra...

Page 6: ...Setup Secual Box ...

Page 7: ...ndroid All you need is a Wi Fi connection at home and an Internet connection on your smartphone Wi Fi 4G 3G Wi Fi connection SIM card GSM network offers optimal security you have a backup in case your home Wi Fi or your cellular network is down SIM card only enables you to interact with your control panel by SMS and phone call You do not need to have an Internet connection at home or on your smart...

Page 8: ...with a SIM card You will need a SIM card if you wish to interact with your Secual Box by SMS and phone call SIM SIM Control panel s SIM card Important Make sure the SIM card is not protected by a PIN code We advise you to choose a plan with unlimited text and 1 or 2 hours of call The SIM card must be compatible with the GSM network Contact your carrier for more information ...

Page 9: ...IFI_XXXXXX the last 6 digits differ on every control panel 3 Open the Secual Box app on your smartphone 4 Create an account and log in from this account 5 Follow the instructions on screen to connect your control panel to your home Wi Fi network A piece of advice Even if your control panel is connected to your Wi Fi network you can add a SIM card in your Secual Box This enables you to receive noti...

Page 10: ...tifications by app Your Secual Box must be connected to your Wi Fi network to set it up by app by SMS 1 From the dashboard of your control panel slide from the right to display the options and click on Settings 2 Select Phone numbers 3 Make sure SMS is selected and edit the numbers as you wish Send by SMS to the telephone number of the SIM card in the control panel 6 The control panel replies SMS ...

Page 11: ... on the App Store and Google Play 2 Create an account and log in from this account 3 Click on Add alarm select SIM card only and follow the instructions During the setup you will be prompted to determine two things Alarm s name The choice of the name for your alarm is up to you This name will appear in the app so that you can identify the alarm Alarm s phone number This is the telephone number of ...

Page 12: ...Daily use ...

Page 13: ...MS numbers can arm the system by SMS By remote control Press on the Arm button of the remote control Arm in Home mode When your system is armed in Home mode all detectors are active except those assigned to the Home zone By app Connect to your alarm and click on Home mode By SMS Send 2 by SMS to the phone number of the SIM card in the control panel Only saved SMS numbers can activate the Home mode...

Page 14: ...lick on Disarm By SMS Send 0 by SMS to the phone number of the SIM card in the control panel Only saved SMS numbers can disarm the system by SMS By remote control Press on the Disarm button of the remote control SOS function The SOS function enables you to trigger your alarm immediately By remote control Press the SOS button on the remote control On the control panel Press the SOS button on the to...

Page 15: ...G 4G coverage How it works 1 Call the phone number of the SIM card in the control panel 2 The control panel picks up type your 4 digit passcode followed by Default passcode 1234 3 A voice prompt confirms if your code is correct 4 On your phone dial the code corresponding to the command Dial Command 1 Arms the system 0 Disarms the system and turns the siren off Stops monitoring without hanging up A...

Page 16: ...rk Remark If the dashboard is greyed out it means you are not connected to your alarm This can be caused by No Internet connection on your smartphone Your Secual Box is not connected to your home Wi Fi network Send by SMS to the telephone number of the SIM card in the control panel 00 The control panel replies System Disarmed AC power on Remark If the level of your control panel s or detectors bat...

Page 17: ...ox app you must have an Internet access on your smartphone On your smartphone with a SIM card in the control panel The control panel sends an SMS notification to every SMS number saved The control panel calls every Phone number saved If you take that call you can decide to stop the siren disarm the system or other functions as listed below by dialing the corresponding code Dial Command 1 Arms the ...

Page 18: ...Settings ...

Page 19: ...ges By SMS there must be a SIM card in your control panel For each setting you want to modify by SMS it works as below Send a code by SMS The control panel replies you with the corresponding settings currently saved in your alarm Copy this SMS and paste it as a reply to the control panel Modify the SMS according to the setting you wish to change before sending back to the control panel The control...

Page 20: ...click on Settings 2 Select Phone numbers 3 Make sure SMS is selected and edit the numbers as you wish Send by SMS to the telephone number of the SIM card in the control panel 6 The control panel replies SMS numbers 1 2 3 4 5 Copy paste then edit case sensitive do not add spaces SMS numbers 1 0600000000 2 0600112233 3 4 5 Ok Important Only the first SMS number will receive notifications in case of ...

Page 21: ... From the dashboard of your control panel slide from the right to display the options and click on Settings 2 Select Phone numbers 3 Make sure Calls is selected and edit the numbers as you wish Send by SMS to the telephone number of the SIM card in the control panel 5 The control panel replies Phone numbers 1 2 3 4 5 Copy paste then edit case sensitive do not add spaces Phone numbers 1 0600000000 ...

Page 22: ... the right to display the options and click on Settings 2 Select Delay 3 Click on Exit delay or Entry delay and adjust the delay as you wish Send by SMS to the telephone number of the SIM card in the control panel 11 The control panel replies Entry delay time 0 300sec 0 Exit delay time 0 300sec 0 Copy paste then edit case sensitive do not add spaces Entry delay time 0 300sec 10 Exit delay time 0 3...

Page 23: ...nd click on Settings 2 Select Siren 3 Enable disable the siren as you wish 4 Set the siren duration as you wish Send by SMS to the telephone number of the SIM card in the control panel 12 The control panel replies Siren volume 0 Mute 1 High 1 Siren ringing time 1 9min 5 Copy paste then edit case sensitive do not add spaces Sirenvolume 0 Mute 1 High 0 Siren ringing time 1 9min 3 Ok ...

Page 24: ...ight to display the options and click on Settings 2 Select Change passcode 3 Type your current passcode and your new passcode Send by SMS to the telephone number of the SIM card in the control panel 13 The control panel replies Disarm password 4 digits 1234 Copy paste then edit case sensitive do not add spaces Disarm password 4 digits 0000 Ok Important If you want to control your alarm by phone ca...

Page 25: ...to display the options and click on Detectors 2 Click on the detector you wish to rename and then tap on the name to modify it Only detectors 1 to 9 can be renamed by SMS Send 91 99 the second digit corresponds to the detector you wish to rename 91 The control panel replies Zones names 1 Copy paste then edit case sensitive do not add spaces Zones names 1 Living room Ok ...

Page 26: ... by moving the jumpers with tweezers according to the drawings below The jumpers are located on each detector s circuit board D0 D3 D0 D3 Normal zone Home zone D0 D3 D3 D0 Delay zone 24h zone What do zones do Normal zone when the system is armed a detector on the Normal zone is active When the system is disarmed the detector is not active Home zone when the system is armed in Home mode all detecto...

Page 27: ...name controls by app by SMS 1 From the dashboard of your control panel slide from the right to display the options and click on Controls 2 Click on the control you wish to rename and then tap on the name to modify it Controls remote controls and keypads cannot be renamed by SMS ...

Page 28: ...ard of your control panel slide from the right to display the options and click on Detectors or Controls 2 On the detector or the control you wish to delete slide left and click on trash icon You cannot delete accessories individually by SMS However you can delete all accessories at once Send 21 The control panel replies Ok ...

Page 29: ... the options and click on Settings 2 Select System language 3 Select the language as you wish Send the code corresponding to the language you want to set For example for English send 0001 The control panel replies Ok All the languages available are listed below English 0001 French 0002 Russian 0003 Danish 0004 Dutch 0005 Italian 0006 German 0007 German 0008 Spanish 0009 Norwegian 0011 ...

Page 30: ... display the options and click on Settings 2 Click on Reset Press the SOS button 1 and the Connection button 3 of the control panel at the same time The control panel beeps 3 times then 2 times as a confirmation that it has reset successfully Important After having reset your control panel all settings will be restored to factory settings All accessories will be deleted from the control panel ...

Page 31: ...ct to the Wi Fi network of your Secual Box or if the network is secured you can reset the Wi Fi by app on the control panel This function cannot be done in the app Press the Connection button 3 of the control panel for 5 seconds The control panel beeps once as a confirmation that it has reset successfully ...

Page 32: ...Accessories ...

Page 33: ...it contains 1 x ES D2A Design Test Connection button Jumpers for zone setup Tamper switch Infrared sensor AA 1 5V LR6 Antenna LED indicator Back view Circuit board Detection scope 110 0m 2m 4m 6m 8m 2m 0m Top view Side view The detector is more sensitive to cross movements than vertical movements Side view Top view ...

Page 34: ...r where the air stream flows frequently 2 2m 25kg Important understanding the standby mode If the detector is triggered more than twice within 3 minutes it switches to standby mode to save power During standby mode the detector is inactive If within the next 3 mintutes a new movement is detected the standby mode is extended by 3 minutes If no movement is detected within the next 3 minutes the sens...

Page 35: ...you have deleted the detector from the control panel you can reconnect it as follows 1 Press once on the Connection button 3 of the control panel 2 Press the Test button at the back of the detector The control panel beeps once the detector is now connected If your control beeps twice the detector was already connected Specifications Power supply DC 3V AA 1 5V LR6 Batteries x 2 Static current 30 uA...

Page 36: ...er and secure the transmitter and magnet with double sided tape on the door and the door frame respectively 1cm max Connection to your alarm system The detectors in your kit are already connected and ready to use If you have deleted the detector from the control panel you can reconnect it as follows 1 Press once on the Connection button 3 of the control panel 2 Separate the magnet from the transmi...

Page 37: ...A 1 5 V Battery x1 Static current 30 uA Alarm current 15 mA Transmitting distance 80 m in open area Radio frequency 433 MHz 75 KHz Housing material ABS plastic Operating conditions Temparature 10 C 55 C Relative humidity 80 non condensing Dimensions LxWxH Transmitter 60 x 45 x 18 mm Magnet 45 x 19 x 17 5 mm ...

Page 38: ...onnected and ready to use If you have deleted a remote control from the control panel you can reconnect it as follows 1 Press once on the Connection button 3 of the control panel 2 Press Disarm on the remote control The control panel beeps once the remote control is now connected If your control beeps twice the remote control was already connected Specifications Power supply DC 3V CR2025 button ba...

Page 39: ...ccessories Precautions Accessories 39 Transmission distance 80 m in open area Radio frequency 433MHz 75KHz Housing material ABS plastic Operating conditions Temperature 10 C 55 C Relative Humidity 80 non condensing Dimensions 57 x 31 x 11 mm ...

Page 40: ...ork you can also connect additional accessories from the app Open the app and log in to your account Connect to your alarm From your alarm s dashboard slide from the right to show the options and click on Detectors or Controls Click on Add detector or Add control and follow the instructions on screen Connect additional sirens Not all sirens have the same way of connecting Please refer to the user ...

Page 41: ...Precautions ...

Page 42: ...e system regularly to make sure the system works properly The control panel is neither waterproof nor moisture proof install it in a shady cool and dry place The case of the control panel is made of ABS plastic Keep away from bright light for a longer lifespan The control panel is not explosion proof Keep away from fire and flames Dispose of the batteries according to local regulations Dismantling...

Page 43: ... dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product To prevent fire or shock hazards do not expose this product ...

Page 44: ...resence of hazardous substances In compliance with European laws This product is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC This product was designed and manufactured in compliance with Directive 2002 95 EC of the European Parliament and of the Council on the restriction of use of certain hazardous substances in electrical and electronic equi...

Page 45: ...eTIGER EUROPE 18 C Rue des Procureurs 7500 Tournai Belgium service etiger com ...

Reviews: