30
29
Usage
Remove the battery activation strip to activate batteries. It will start self-testing
for one minute.
Mode Setting
Test Button
Connect to alarm panel
Press the connect key on the alarm panel, and then press the test button of the
sensor twice to send alarm signal. When one beep is heard, they are connected. To
check if they are connected successfully, arm the system, and trigger the sensor
again, if there is an alert, the connection is successful.
2m
Ground
The detector is more sensitive to the cross movement than to the vertical
movement, so th e per forma n ce of de tec to r is best wh e n th e de tec tion
direction is vertical to the walking direction of people.
Installation & Notices
Avoid mounting the detector close to windows, air conditioner, heater, refrigerator,
oven, sunshine and places where the temperature changes fast or the air stream flows
frequently.
If two detectors are installed in the same detection scope, please adjust the locatio to
avoid interference and false alarm.
Top view
Side view
Testing (Walk Test)
A. After installation, power on the detector. After one minute self-testing, press the
test button, walk in the scope (from left to right or from right to left) and watch the
LED indicator to make sure the detector is working.
B. The LED indicator flashes once when body movement is detected.
C. Adjust the detector angle accordingly to achieve the best detection effect.
Testing mode:
After self-testing, press the test button, the sensor enters testing mode, and
detects once every 10 seconds. After 3 minutes, the LED flashes twice, and the
sensor enters the working mode.
Working mode:
In working state, if the sensor is triggered twice within 3 minutes, it will enter
sleeping mode to save power. After no movement within next 3 minutes, the
sensor goes back to the working mode.
Fix the bracket on the wall with screws and attach the detector to the bracket.
Adjust installation height or bracket to change the detection distance and
angle. It is recommended to mount it at the height of 2m from the ground.
Directive
Detection Scope
2m
4m
6m
8m
0m
0m
2m
110°
Top view
Side view
Specifications
Power supply
Static current
Alarm current
Detection scope
Transmitting distance
DC 3V (AA 1.5V LR6 Battery x 2 pcs)
≤ 50uA
≤ 9.5mA
8m/110°
≤ 80m (in open area)
Radio frequency
Housing material
Operation Condition
Detector dimensions (L x W x H)
Bracket dimensions (L x W x H)
315MHz or 433MHz (± 75KHz)
ABS plastic
Temperature: -10°C~55°C
Humidity: ≤80%RH (non-condensing)
108 x 52 x 36.8 mm
52 x 30 x 26.5 mm
This product bears the selective sorting symbol for waste electrical and electronic
equipment(WEEE).This means that this product must be handled pursuant to European.
2002/96/EC in order to be recycled or dismantled to minimize its impact on the environment.
For further information,please contact your local or regional authorities.
Electronic products not included in the selective sorting process are potentially dangerous for
the environment and human heath due to the presence of hazardous substances.
In compliance with European’s law.
This product was designed and manufactured in compliance with Directive 2002/95/EC of the
European Parliament and of the Council on the restriction of use of certain hazardous substances in
electrical and electronic equipment (RoHS Directive - Rohs) and is deemed to comply with the
maximum concentration values set by the European Technical Adaptation Committee(TAC).
Standards