Channel Configuration/Status Register
Bit
6
Fault Status
‘1’
MCOR Power Module Faulted
‘0’
MCOR Power Module OK
5
Ramping
‘1’
Ramping in progress
‘0’
Ramping done
4
Standardized
Direction
‘1’
Falling
‘0’
Rising
Not implemented
3
Ramp Mode
‘1’
Immediate, no ramping
‘0’
Normal Ramp Mode Selected
2
Closed Loop
(Auto Trim)
‘1’
Closed Loop
‘0’
Open Loop
Not implemented
1
Fast FeedBack
‘1’
Channel being used for Fast Feedback
‘0’
Normal MCOR functionality
Not implemented
0
Configured
Cleared by power on, set to indicate the
channel has been configured. The Channel
will not respond to setpoint commands unless
the configure bit is set.
Configuration Set/Reset Registers
Bit
4
Standardized Direction
Not implemented
3
Ramp/Immediate
2
Closed Loop
Not implemented
1
Fast FeedBack
Not implemented
0
Configured
Ramp Rate
Bit
[31:00]
Ramp Rate
Int32 in µA/sec
Bulk Supply Register Information
Offset
Reg
Base 0x0400
0x04
1
Bulk Supply Voltage 0-5V => 0-30V
Int32 in µV
0x0C
3
Ground Fault Current
Int32 in µA
0x1C
7
Bulk Supply ADC Full Scale Voltage
Int32 in µV
0x24
9
Bulk Supply ADC Full Scale Ground Current
Int32 in µA
0x28
A
Ground Fault Current Threshold
Int32 in µV
0x30
C
Configuration/Status Register
UInt32
0x34
D
Set Configuration Register
UInt32
0x38
E
Reset Configuration Register
UInt32