![EtherCAT TMCL Firmware Manual Download Page 87](http://html1.mh-extra.com/html/ethercat/tmcl/tmcl_firmware-manual_2432550087.webp)
TMCM-1310 TMCL Firmware V1.11 Manual (Rev. 1.16 / 2014-MAR-19)
87
www.trinamic.com
9.7
Torque Mode
In torque mode, the motor is commanded to run with fixed torque output. The velocity varies depending
on the actual load. The motor runs as fast as it can for a certain load situation. In this mode, the
commutation angle is always 90 degrees ahead for maximum torque output.
With axis parameter 14, the
target phase current amplitude
can be configured [mA] to the desired value. It
is fixed as long as the motor is running in torque mode. The current amplitude will not be regulated. The
range of axis parameter 14 covers the maximum current range allowed by the TMCM-1311, which is up to
4200mA peak phase current. The moving direction is defined by the sign of axis parameter 14.
H
OW TO USE TRAPEZOID RAMPS IN TORQUE MODE
:
-
Set the
current
slope
with axis parameter 20. This way, trapezoid ramps with acceleration and
deceleration of the drive can be generated.
-
Set a
start and stop value
for the ramp using axis parameter 141.
-
To get the actual state of the ramp, the
actual current in torque mode
can be read out with axis
parameter 19. This parameter can also be set to specify a value for the actual current, if necessary.
A
XIS PARAMETERS RELATED TO TORQUE MODE
Number Axis parameter
Description
Units / Default
Acc.
14
CL torque mode
target current
Target RMS current value for torque mode.
Positive and negative values define rotation
direction.
-
Writing a target value to this parameter
automatically switches to torque mode.
-
Reading provides the actual configured
target current while in torque mode.
-
Reading while in other modes (velocity
mode,
position
mode)
provides
information on the actual advance angle
(in these cases the unit is microsteps).
The maximum current that can be configured
can be read out using axis parameter 15.
-3000… +3000
[mA]
RW
torque
mode
R
velocity
and
position
mode
15
Maximum
possible current
Based on axis parameters 6 and 179 this
parameter returns the maximum possible
RMS current.
0….+3000
[mA]
R
19
CL torque mode
actual current
Actual current in torque mode
-3000… +3000
[mA]
RW
20
CL torque mode
slope
Slope in torque mode (related to acceleration
and deceleration).
[mA/s]
RW
141
CL torque mode
start/stop
current
Start and stop current in torque mode.
0… +3000
[mA]
RW
150
Motor current
Actual motor current
[mA]
R
151
Current Phase A
Actual peak current Phase A
[mA]
R
152
Current Phase B
Actual peak current Phase B
[mA]
R
153
Supply Voltage
Actual value of supply voltage
[1/10 V]
R
154
DC Current
Actual DC current of the complete
motor
[mA]
R
155
Module
temperature
Actual temperature of the module
[°C]
R