background image

30

Liquid  Propane  Gas(LPG)  Conversion

Gas Packing-1

Valve  Adaptor

Gas  Val ve
Flange

Conne ctor
Bracket

Gas Valve

Packing

Replace  NG  Valve  Adaptor  With  LPG  Adaptor

Gas Packing-2

Gas Packing-3

Loosen and remove 5 screws securing the Gas Valve Flange. Remove the Gas Valve Flange, Packing and Valve

Adaptor(NG). Replace Valve Adaptor(NG) with Valve Adaptor(LP). Reverse the steps above by reassembling the
packing, Gas Flange and Connector Bracket. Make sure all screws and secure and tightened.

Change Dip Switch No.8 position from left to right.

8

7

6

6 .

7 .

Reassemble  Water  Heater  Casing

8 .

Attach Top Panel and back on frame of the water heater and tighten the 2 screws. Attach Exhaust Top on Top
Panel and tighten the 4 screws. Attach Control Panel Assembly to frame and tighten the 2 screws on the bottom

of the panel. Remove The NG Label. Stick LPG label on the Panel.

PROPANE    GAS

Summary of Contents for GU26DV

Page 1: ...ay WARNING California Proposition 65 lists chemical substances known to the state to cause cancer birth defects death serious illness or other reproductive harm This product may contain such substance...

Page 2: ...be filled with water Water must be running from the hot water faucet before turning the main gas valve to the water heater to ON WARNING CAUTION If you do not follow these instructions exactly a fire...

Page 3: ...al gas valve located on the outside of the unit to the off position Wait five 5 minutes to clear out any gas If you smell gas STOP Follow B in the safety information above If you don t smell gas go to...

Page 4: ...4 Parts Diagrams for Model GU32DV 505 11 12 1321...

Page 5: ...06 1 7 Panel Bottom 151010009 1 8 Control Panel Assembly 301080170 1 9 Temperature and Pressure Relief Valve 194010281 1 10 Intake Collar Assembly 307060517 1 11 Top Packing 151010200 1 12 Plug 601020...

Page 6: ...Parts Diagrams for Model GU26DV 505 11 12 1261 6...

Page 7: ...06 1 7 Panel Bottom 151010009 1 8 Control Panel Assembly 301080170 1 9 Temperature and Pressure Relief Valve 194010281 1 10 Intake Collar Assembly 307060517 1 11 Top Packing 151010200 1 12 Plug 601020...

Page 8: ...will turn off automatically WHATTO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier fro...

Page 9: ...re Press the HOT or COLD Temperature Setting Button with unit ON Temperature setting is only adjustable when the water heater is not in use The maximum water temperature setting can be limited by DIP...

Page 10: ...a self cleaning system initiated by the flow of water Build up of sediment in faucet aerators shower heads and screens could impair water flow and cause the water heater to deliver less than its full...

Page 11: ...n A secondary air hole thermistor short open A vent condition is not normal Temperature too high on a burner thermistor Mixing control valve is not connected Mixing control valve initialization failur...

Page 12: ...bove sea level contact the manufacturer for high 0 5 to 9 1 Gal min 100 102 104 106 108 110 112 114 116 122 131 140 149 158 167 F 15 steps 9 1 Gal min ITEM MODEL NAME TYPE IGNITION DIMENSIONS OPERATIO...

Page 13: ...bs 120 VAC 60 Hz Specifications GU26DV 505 11 12 1261 Indoor Sealed Direct Vented Direct Ignition 13 Natural Gas Max 180 000 btu hr Min 47 500 btu hr L P Gas Max 180 000 btu hr Min 47 500 btu hr 45 F...

Page 14: ...himney or gas vent The appliance should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the appliance or to lower floors of the structu...

Page 15: ...Relief Valve x 1 Intake Top x 1 O Ring G95 x 1 Exhaust Collar x 1 Valve Adaptor x 1 Orifice for LPG x 1 LPG Label x 1 Top Packing x 1 Mesh Screen x 2 Self Tapping Screw T4x16 x 5 Philips Head Screw M...

Page 16: ...4 screws Install the T P Relief Valve on the side of unit Make sure the T P Relief is secured tight to prevent water leak For indoor installation please install the Top Packing before connecting PVC o...

Page 17: ...xhaust outlet and air inlet terminals shall terminate at least 18 inches above the roof surface 0 clearance for 4 PVC ABS OR CPVC Schedule 40 piping from combustible surfaces The venting system must b...

Page 18: ...cal or Horizontal run in Length 40 ft Power Direct Venting Rule 18 When determining the installation location for a power direct vent water heater snow accumulation and drifting should be considered i...

Page 19: ...haust gases The venting system must be installed in a manner which allows inspection during the installation of the venting pipes and joints as well as periodic inspec tion after installation as requi...

Page 20: ...ional Standard Institute and Ameri can Society for Testing and Materials ANSI ASTM stan dards in the United States CEMENTING PVC ABS or CPVC PIPE and FITTING All primers cleaners and cements must meet...

Page 21: ...om the center line of the terminal E 12 inch min clearance to unventilated soffit F Clearance to outside corner G 2 feet clearance to inside corner formed by two exterior walls H 4 feet clearance to e...

Page 22: ...o the left Complete the rest of the vent pipe installation to thewaterheater sventconnector fittingontheblower outlet If necessary support horizontal run as previously mentioned The vertical inlet and...

Page 23: ...3 7 9 3 4 7 3 2 3 3 0 8 2 7 6 2 5 3 2 1 3 1 1 4 2 2 0 6 1 4 9 7 1 2 1 3 1 0 4 0 9 1 4 8 3 5 7 7 2 7 2 5 6 7 8 6 3 1 5 6 7 5 1 1 4 4 0 1 1 2 3 3 0 8 2 3 0 0 1 8 5 9 1 5 6 0 1 4 1 8 1 2 7 6 1 1 8 2 1 0...

Page 24: ...Be careful not to reverse the hot water outlet and cold water supply line connections to the water heater This will cause your heater to operate dan gerously and void warranty Make sure the hot and c...

Page 25: ...ions in the State of California CAUTION California Law requires that residential water heaters must be braced anchored or strapped to resist falling or horizontal displacement due to earthquake motion...

Page 26: ...be electrically grounded Label all wires prior to disconnection when servic ing controls Wiring error can cause improper and dangerous operation Verify proper operation after servicing CAUTION The wa...

Page 27: ...28 PV switch 5 OFF switch 4 Test selection switch 2 switch 3 Temperature selection 1 switch 2 Temperature selection 2 switch 1 Temperature selection 3 O N 8 7 6 5 4 3 2 1 switch 8 Reserved switch 7 Re...

Page 28: ...m axim umtem perature by selection switch O N 3 2 1 104 O N 3 2 1 110 O N 3 2 1 114 O N 3 2 1 122 O N 3 2 1 131 O N 3 2 1 140 O N 3 2 1 149 O N 3 2 1 167 Limitation of maximum temperature by selection...

Page 29: ...2 screws securing the Control Panel Assem bly to the frame and remove the Assembly from Water Heater Loosen 2 screw and the nut of the gas pipe and insert with Orifice LP Tighten the loose nut to mak...

Page 30: ...Valve Adaptor LP Reverse the steps above by reassembling the packing Gas Flange and Connector Bracket Make sure all screws and secure and tightened Change Dip Switch No 8 position from left to right 8...

Page 31: ...31 Recirculation System With A Grand Hall Water Heater Do not run circulation pump over two hours when install with timer Pump on time is should be less than two hours CAUTION...

Page 32: ...You are responsible for shipping charges of such replacement parts This Warranty does not cover any failures or operating difficulties due to accident abuse misuse alteration misapplica tion vandalis...

Reviews: