Remove Casing From Water Heater
Loosen 2 screws securing the Front Panel on the
bottom front, and push downwards to remove the Front
Panel.
Control Panel
Assembly
Fixing Screw
Loosen 2 screws securing the Control Panel Assem-
bly to the frame, and remove the Assembly from Water
Heater.
Loosen 2 screw and the nut of the gas pipe, and insert
with Orifice LP. Tighten the loose nut to make sure the
orifice is installed properly.
Change the NG orifice to LP orifice
29
1.
2 .
3 .
Liquid Propane Gas(LPG) Conversion
Orifice LP
Nut
Gas Tube
Fixing Screw
Front Panel
Fixing Screw