ETCR 9200 Manual Download Page 10

 

Peak 

Maintenance

 

Automatically  maintain  the  height  of  the  tes

t  value

usually  in  the  test  mode  press 

PE

AK

  key

LCD  top  right  corner  will  display 

PE

that  is,  to  keep  open  the  PEAK  function,  th

en  press 

PEAK

  key  to  cancel  this  function

 

Circuit Voltage 

Test    insulating sheath wires

60kV 

or bare 

wire t

35kV 

(operated with insulation rod) 

Data 

Preservation 

Under general test mode, press 

HOLD

 button 

to  preserve  data, 

DH

  symbol  display.  then 

press 

HOLD

  Key  to  cancel  (

HOLD

  symbol 

display) 

Data Access 

MR

 

 symbol indicates, it can read the stored 

data by turning upwards and downwards.   

Overflow Display 

Exceed measurement range overflow function: 

OL    A

 symbol display 

* No signal 

Indication 

When  the  receiver  has  not  received  transmit 
signal, it will display 

no- -

symbol 

Auto Shut Down 

About 15 minutes after booting, the meter will 
shut down automatically, in order to decrease 
the battery consumption. 

Battery Voltage 

When  the  battery  voltage  is  below  4.8V,  the 
symbol  of  battery  voltage

       

will  show  to 

remind to replace battery. 

Weight

 

Tester

    About 620g (Including battery) 

receiver

About 220g (Including battery) 

Total  quality  of  meter:  about  2.3kg(including 

insulation rod and battery)

 

Work 

Temperature and 

Humidity

 

-10

~40

80%Rh 

Summary of Contents for 9200

Page 1: ......

Page 2: ......

Page 3: ...ration 10 1 Power On Off 10 2 General Test 11 3 PEAK Test 13 4 Data Maintenance 13 5 Data Memory 13 6 Data Reference 14 7 Data Deletion 14 8 Data Transmission 14 B Operation of Receiver 14 1 Power On Off 14 2 Data Reception 15 3 Data Maintenance 15 4 Data Memory 15 5 Data Reference 15 6 Data Deletion 16 VIII Replacing Batteries 16 IX Accessories 17 ...

Page 4: ......

Page 5: ...ngerous of high voltage transmission line the operator must get strict training and the relevant certification on high pressure operation of the state before using this meter and making a field test u It is forbidden to use the meter test voltage more than 35 kV convergence of bare wire or bus u Please pay attention to marked words and symbols on panel or backboard of this meter u Please do not pu...

Page 6: ...tely and seal it up for keeping at once which shall be dealt with by qualified authorization agency u The danger symbol on the meter and the manual the user must make safe operation according to the indication u The extremely dangerous symbol the user must make safe operation according to the indication u It suggests that this meter shall be made insulation intensity test at least once annually AC...

Page 7: ...test save the physical power of user to ensure the high precision high stability and high reliability of perennial uninterrupted measurement ETCR9200 Series H L Voltage Clamp Current Meter connected with insulation rod can be used to measure the high voltage current of the cable under 60KV with an insulating or bare wire cable 35kV on line current measurement also having peak maintenance data pres...

Page 8: ...r characteristics II Electrical Symbols Extremely Dangerous The operator must strictly abide by the safety rules Otherwise there is electric injury danger causing personal damage or casualty accident Dangerous The operator must strictly abide by the safety rules Otherwise there is electric injury danger causing personal damage or casualty accident Warning It must strictly abide by the safety rules...

Page 9: ...f measurement 0 00mA 1000A 50Hz 60Hz Auto Identification Resolution 0 01mA Shift 0 00mA 1000A Automatic Shift Test Accuracy 23 5 80 RH 0 00mA 299mA 1 3dgt 300mA 49 9A 1 5 5dgt 50 0A 199 9A 2 5dgt 200A 600A 3 5dgt 601A 1000A 4 5dgt Sampling Speed About 2 times second Display Mode 4 digital LCD display LCD Dimension Tester LCD 35mm 21 5mm Receiver LCD 47mm 28 5mm Meter Dimension Tester 218mm 135mm 6...

Page 10: ...l indicates it can read the stored data by turning upwards and downwards Overflow Display Exceed measurement range overflow function OL A symbol display No signal Indication When the receiver has not received transmit signal it will display no symbol Auto Shut Down About 15 minutes after booting the meter will shut down automatically in order to decrease the battery consumption Battery Voltage Whe...

Page 11: ...ulation Intension Tester receiver AC 2kV rms Between core and shell Insulating rod AC 100kV rms 5 sections insulating rod all connections between both ends Structure Anti Dripping Type II V Structure 1 Insulating rod connecting head 2 clamp boot sector 3 LCDdisplay 4 PEAK key start LCD display PE 5 HOLDkey 6 POWER key 7 POWER light 8 Insulating rod 5 sections ...

Page 12: ...lay please replace battery in time OL A This symbol indicates that the current on test has exceeded the maximum measurement limit of the meter MEM Memory mode it will display during the data storage process Full symbol when the storage memory has been filled with 99 groups of data it will display FULL symbol by flash which means it cannot continue to store data ...

Page 13: ... not in test mode or adjust the location and distance from receiver 9 PE symbol press PEAK display Indicates start PEAK test HOLD DH symbol press HOLD display lock the data 2 Display Demonstration The current on test is 0 002A 2mA Locked display Data The data is automatic stored as group 3 The current on test is 160 5A The current on test is 571A Low battery symbol please replace Look up data of g...

Page 14: ... on the instrument will displays the LCD screen entering normal testing mode If LCD display is relatively dark after power on it is possible that battery voltage is a bit lower Please replace battery 15 minutes after powering on the meter if it remains idle an auto power off procedure starts to preserve the battery life and LCD will continue flash until the complete switch off takes place after 30...

Page 15: ...ty accident u Dangerous It is forbidden to use the meter test voltage more than 35 kV convergence of bare wire or bus Otherwise there is electric injury danger causing personal damage or equipment damage Dangerous It cannot be used to measure the circuit over 600A voltage Otherwise there is electric injury danger causing personal damage or equipment damage General Test In the process of test LCD w...

Page 16: ...g in Firstly to tear down the tester and then the insulation rod avoiding the impact of meter to ground surface After normal boot place the lead in the middle of clamp transducer domain The drop down instrument clamped conductor to be tested showing the result on LCD display If showing OL A it means the lead current on test has exceeded the maximum volume on the level Please select a higher gear l...

Page 17: ...the meter is removed away from the lead on test the test result will be kept consistently suitable for the circuit test on those LCD data hard to be read directly Under the normal testing mode press PEAK button LCD display PE enter PEAK testing mode That means the meter will display and automatically keep the maximum value in the test Under any other mode it must be returned to normal testing mode...

Page 18: ...delete all the data in storage and return to normal testing mode During the deletion of data it will display dEL symbol 8 Data Transmission ETCR9200B has the function of wireless data transmission When the Meter under testing mode the test result will be transferred to receiver by wireless transmission and the receiver will display test result real time being clear at a glance Only under testing m...

Page 19: ...test result real time If it has not received any signal the receiver will search signals constantly and display no symbol dynamically 3 Data Maintenance Under Data Reception mod press HOLD button keep LCD display HOLD symbol indication Press HOLD button once again to relieve data lock return to data reception mode HOLD symbol display 4 Data Memory Under Date Reception mode press HOLD button to mai...

Page 20: ...s cover board is not well closed it is forbidden to make test Otherwise it is dangerous Pay attention to the polarity of battery in case of damage to the meter Do not mix in the use of new and old batteries 1 When the battery voltage is below 4 8V the meter will display symbol indicating the batteries have no sufficient power content Please replace batteries 2 Power off to make sure the meter is u...

Page 21: ...ssories Tester 1PCS Receiver ETCR 9200B special 1PCS Insulation Rod 1M Section 5 Sections Meter Box 1PCS Battery Alkaline Dry Battery AAA 4 PCS or 8 PCS User s Manual Maintenance Card Conformity Certificate 1SET ...

Page 22: ... Electronic Technology Company Address F 3F No 4 Pengshang Zhifu Road Jiahe Baiyun District Guangzhou Guangdong China Post Code 510440 Tel 86 20 62199556 62199554 Fax 86 20 62199550 E mail info etcr cc Website www etcr cc ...

Page 23: ......

Reviews: