Catalogue
Page 1: ...Catalogue ...
Page 2: ...Operation 10 1 Power On Off 10 2 Gear Shift Choice 11 3 General Test 11 4 PEAK Test 13 5 Data Maintenance 14 6 Data Memory 14 7 Data Reference 14 8 Data Deletion 14 9 Data Transmission 15 B Operation of Receiver 15 1 Power On Off 15 2 Data Reception 15 3 Data Maintenance 16 4 Data Memory 16 5 Data Reference 16 6 Data Deletion 16 VII Replacing Batteries 17 VIII Packing List 17 Enclosed with Tester ...
Page 3: ...cation on high pressure operation of the state before using this meter and making a field test u It is strictly forbidden to use this meter to test the wire or convergence generatrix without any insulation u Please pay attention to marked words and symbols on panel or backboard of this meter u Please do not put or store this meter in the place of high temperature with moisture with frozen dew or w...
Page 4: ...h mark in this manual it is only limited to ETCR9000A infrared transmission data type Profile Ⅰ ETCR9000 Series H L Voltage Clamp Meter has broken through the traditional structure which is specially well designed for measuring high voltage current adopting the latest CT technology and integrated mask digital technology formed by composition of a special use clamp meter with a high voltage insulat...
Page 5: ...ions It can also replace the H L voltage transforming ratio tester that is to detect the high and low current for primary circuit and secondary circuit separately and then calculate to conclude the change of high and low pressure The insulation rod is light and convenient with the advantages of anti moisture high temperature resistance anti impact bending resistance high insulation flexibility and...
Page 6: ...ion suitable for dark place LCD Dimension 47mm x 28 5mm Meter Dimension W H T 76mm 255mm 31mm Clamp Diameter φ48mm Sampling Speed Around 2 times second Measurement Scope 1mA 600A 50 60Hz Auto Identification Resolution Rate 1mA Measurement Range 10A 600A Double measurement ranges can be switched by manual and it can be transferred automatically within each measurement range Test Precision 23 5 Belo...
Page 7: ... by turning upwards and downwards Overflow Display Exceed measurement range overflow function OL A symbol display No signal Indicator When the receiver has not received transmit signal it will display no signal dynamically Auto Shut Down In about 15 minutes after booting the meter will shut down automatically in order to decrease the battery consumption Battery Voltage When the battery voltage is ...
Page 8: ...g Type II Ⅳ Structure 1 Transducer clamp including transducer domain 2 Tester 3 Brand Sign 4 Product Name 5 LCD Display 6 Peak Test Mode Indicator 7 HOLD Key Key Combination 8 POWER Key Key Combination 9 Product Type 10 600A Level Indicator 11 10A Level Indicator 12 RANGE Measurement Range Switch Key 13 Insulation Rod Connector 14 Handle ...
Page 9: ...has exceeded the maximum measurement limit of the meter MEM Memory Mode it will show during the storage process of the data FULL Symbol when the memory data has been filled with 99 groups it will show FULL symbol by flash which means it cannot continue to store data MR data reference symbol which is shown during referring to data meanwhile it will show the serial number of data in storage End exit...
Page 10: ... is 160 5A The current on test is 571A Display symbol for low battery voltage Please replace battery Refer to data of group 3 in storage The current on test is 160 5A FULL flash display Memory are full of 99 groups It cannot store more unless delete the memory Data Delete Indicator dEL ...
Page 11: ...ay entering normal test mode If LCD display is relatively dark after power on it is possible that battery voltage is a bit lower Please replace battery In 15 minutes after power on of the meter LCD will continue flashing to give hint for automatic power off after 30 minutes for continuous flash of LCD it will shut down automatically in order to lower the battery consumption In case of LCD continuo...
Page 12: ...oose 10A or 600A level and the relevant indicator light will light If the current on test is unknown please choose 600A level firstly and then make the most suitable gear level according to the test result Under data reference mode both gear shift indicator and PEAK light are not bright 3 General Test High voltage extremely dangerous It must be operated by qualified staff that has acquired authori...
Page 13: ... connected in right position and then to connect tester avoiding the impact of meter to ground surface Make sure to use specially equipped insulation rod to connect with the meter After test it should incline the insulation rod accordingly on drawing in Firstly to tear down the tester and then the insulation rod avoiding the impact of meter to ground surface After normal boot place the lead in the...
Page 14: ...general test mode automatically Attention For the sake of safety on testing strong current as long as the correct operation test has been finished on confirmation please remove the meter away from the lead on test 4 PEAK Test PEAK Test Peak Test In the process of test the meter will make automatic comparison on the changes in measured current indicating the maximum average value and maintain it wh...
Page 15: ...ode press HOLD button to maintain data meanwhile the meter will automatically form serial numbers and memory the current preserved data During the storage MEM symbol will show once by flash This meter can memory 99 groups of data in case of full storage FULL symbol will show by flash continuously and it cannot continue to memory until cleaning out the previous memory 7 Data Reference Under general...
Page 16: ...e the reception distance will gradually shorten In case that the battery voltage is badly insufficient it is possible to have no way to receive data When the battery voltage is 5V the reception distance is about 7m B Operation of Receiver 1 Power On Off Press POWER button for power on LCD display entering receiving data mode If LCD display is relatively dark after power on it is possible that batt...
Page 17: ... maintain data meanwhile the receiver will automatically form serial numbers and memory the current preserved data During the storage MEM symbol will show once by flash This receiver can memory 99 groups of data in case of full storage FULL symbol will show by flash continuously and it cannot continue to memory until cleaning out the previous memory 5 Data Reference Under receiving data mode press...
Page 18: ...he use of new and old batteries 1 When the battery voltage is below 4 8V the meter will show symbol indicating the batteries have no sufficient power content Please replace batteries 2 Power off to make sure the meter is under the state of power off To loosen two screws of the battery cover board open the cover board to replace brand new qualified batteries on It should pay special attention on th...
Page 19: ...PCS Receiver 1PCS Insulation Rod 1M Section 5 Sections Meter Box 1PCS Battery Alkaline Dry Battery AAA 4 PCS or 8 PCS User s Manual Maintenance Card Conformity Certificate 1SET Enclosed with Tester Assembly Drawing ...
Page 20: ...tai Electronics Technology Co Ltd Address 3rd Building B Xianbei Industry Zone Beiji Baiyun Road Guangzhou City Postal Code 510440 Tel 86 20 36282512 36282505 Fax 020 36282515 Email etcr vip 163 com Website http www etcr cc ...