E-Gate max
Local operation
19
Pressing
[Edit]
and turning the encoder dial opens
submenu T02
in which you can set the timing mode for
the DMX output lines.
(see also the Appendix: DMX timing parameters)
DMX timing T02
[Edit]
Press
[Edit]
and turn the encoder dial
Select the DMX output line:
Display: Meaning:
OUT A
DMX output A
OUT B
DMX output B
OUT C
DMX output C
OUT D
DMX output D
Press
[Edit]
again and turn the
encoder dial
Select the DMX timing mode:
Display: Meaning:
slow
Slow
medium
Medium
fast
Fast
Pressing
[Edit]
and turning the encoder dial opens
submenu
T03
. In this menu you set the time required to
detect a DMX input signal error. This time applies to all
DMX inputs. The default value is 2 seconds.
Note: The timeout period starts as soon as 1 second
elapses in which no DMX packets were received
Timeout T03
DMX IN t=2 s
Press
[Edit]
and turn the encoder dial
Select the timeout period:
Display: Meaning:
t=1 s
Timeout period from 1 to 60 seconds
for a DMX input signal error
...
t=60s