E-Gate max
Local operation
16
Menu M06 (System)
Menu for system settings
System M06
submenu [Edit]
Turning the encoder dial opens
submenus S01 through S04
:
Pressing
[Edit]
and turning the encoder dial opens
submenu S01
in which you can set the type of network
protocol for the Ethernet.
Mode IN/OUT S01
UDP&CAN -> UDP
Settings
UDP&ACN -> UDP
IPX ->
IPX
UDP&IPX -> UDP
UDP
UDP&ACN -> IPX
IPX -> UDP
Pressing
[Edit]
and turning the encoder dial opens
submenu S02
in which you can set the logical network to
integrate several venues or studios in a network, for
example.
Range of values: 0 to 9
Logical S02
network: 0
Pressing
[Edit]
and turning the encoder dial opens
submenu S03
in which you can set the IP network mask.
This mask can be used to set up more than 255 addresses
per network.
IP netmask S03
255.255.255.000
Pressing
[Edit]
and turning the encoder dial opens
submenu S04
in which you can set the address of the IP
gateway. This address is the address of the device that
allows access to another network.
IP gateway S04
192.009.200.254