24
Register
Description
Read
3:1062 + (n-1)
Kinetic Energy
–
Entry n
n = 1 to 120
0
–
315.0 J (0
–
2788.2 lbs-in)
3:1282
–
3:1500 Reserved
N/A
Modbus Error Log
3:1501
Slave Access Failure Type
This register may be read to view details of
the last
Slave Device Failure
or
Illegal Data
Address
exception response.
0
–
12
3:1502
Slave Access Failure Bank
Contains the Modbus bank in which the last
Slave Device Failure
or
Illegal Data Address
exception response occurred. The bank
returned does not include any address
information.
0
–
4
3:1503
Slave Access Failure Register
Contains the register number at which the
last
Slave Device Failure
or
Illegal Data
Address
exception response occurred. The
address returned does not include any
bank information. For example,
abcd
is
returned for an error at address 0:
abcd
,
1:
abcd
, 3:
abcd
, or 4:
abcd
.
0
–
65535
3:1504
–
3:1510 Reserved
N/A
Firmware Error Log
3:1511
Number of Log Entries
0 - 10