21
Register
Description
Read
1:0012
New Velocity Indicator
0
–
No new velocity measured
since last polled
1
–
New velocity measured since
last polled (value resets to 0 once
it has been read)
Kinetic Energy Alarm Status
1:0013
Consecutive Hard Arrival Alarm Status
0 - Consecutive Hard Arrival
Statistic under threshold
1 - Consecutive Hard Arrival
Statistic over threshold
1:0014
Dangerous Arrival Alarm Status
0 - Dangerous Arrival Alarm
Statistic under threshold
1 - Dangerous Arrival Alarm
Statistic over threshold
1:0015
Cumulative Hard Arrival Alarm Status
0 - Cumulative Hard Arrival Alarm
Statistic under threshold
1 - Cumulative Hard Arrival Alarm
Statistic over threshold
1:0016
Cumulative Kinetic Energy Alarm Status
0 - Cumulative Kinetic Energy
Alarm Statistic under threshold
1 - Cumulative Kinetic Energy
Alarm Statistic over threshold
Input Registers
Table 11 - Available Input Registers
Register
Description
Read
Controller Information
3:0001
–
3:0002 Serial Number
Double Word format: 0 - 99999