1. Lift the luminaire to the installation location. We recommend that two people lift the

luminaire.

2. Secure the luminaire in place using the previously installed truss clamps or other installation

hardware. Secure the attachment hardware in place by tightening the hardware (wing bolt or
other hardware), ensuring the luminaire is securely installed and supported to the truss.

Note:

The installation must follow local codes and standard practices for overhead

rigging. When the luminaire is mounted in an overhead rigged position, you must also
secure it in place using a safety cable.

3. Attach a safety cable to the luminaire.

a. Loop one end of the safety cable around the enclosure handle and attach the clip onto the

cable.

b. Loop the other end of the cable around the truss or pipe structure, then secure the clip

onto the cable.

Connect Data and Power

Connect DMX-512

ETC recommends using the following standard pinout when preparing DMX cable (Belden 9729 or
equivalent) with an XLR connector. The second data pair in the recommended cable type is not used
by the Relevé Spot luminaire and should be capped off and tied back for future service.

DMX-512 Pinout for 5-pin XLR (EIA-485)

DMX Thru Receptacle

Pin #

Use

DMX Input Receptacle

Push

1

2

3

4

5

*XLR pins viewed from the
outside

1

Common (shield)

1

2

3

4

5

*XLR pins viewed from the
outside

2

Data - (typically black wire)

3

Data + (typically white wire)

4

unused

5

unused

Connect DMX

1. Connect the prepared DMX cable with the 5-pin XLR connector from the console or routed

lighting network to the luminaire DMX Input receptacle.

2. If required, connect the prepared DMX cable with the 5-pin XLR connector from the DMX Thru

connector on the luminaire to the next device in the control run.

3. Dress all cables so they will not interfere with the luminaire movements during normal

operation.

Terminate DMX-512

The last luminaire in the DMX control run must be terminated to prevent signal reflections. Signal
reflections cause noise on the data line, resulting in corrupted data between the control source and
the luminaire. Use a DMX termination plug 5-pin XLR male (available from ETC; order part number
SGE1507).

Summary of Contents for Releve Spot

Page 1: ...exposed to extreme cold or heat outside of the operational range see Environment on the next page moisture or dust Do not project the light beam onto combustible surfaces or materials The minimum dis...

Page 2: ...bjects IPx0 indicates no protection against liquid contact and ingress of liquid objects Attach Clamp Mounting Rails CAUTION Risk of Personal Injury Overhead mounting requires extensive experience inc...

Page 3: ...he next page or other compatible hardware for installation The clamp mounting rails feature a safe latching system for secure fit to the hanging points on the enclosure 1 Install the truss clamps not...

Page 4: ...n and tilt homing at power on with minimal movement You can install the luminaires closer together if you restrict the pan and or tilt movement using the features provided for pan and tilt in the Opti...

Page 5: ...e Belden 9729 or equivalent with an XLR connector The second data pair in the recommended cable type is not used by the Relev Spot luminaire and should be capped off and tied back for future service D...

Page 6: ...following wire color code chart Wire Color Code International Standard Wire Color Code US Standard Connection Type Terminal Green Yellow Green Earth Ground Blue White Neutral N Brown Black Line Live...

Page 7: ...luminaires whether or not they utilize LEDs from the same production batch Operating in Direct Mode bypasses this calibration and multiple luminaires may produce slightly different outputs when contr...

Page 8: ...aire is recommended to ensure optimal performance for the life of the luminaire Note Any service or maintenance that you perform on your Relev Spot luminaire is at your own risk WARNING RISK OF DEATH...

Reviews: