15
BluesSystem Installation Manual
Low Voltage Outputs
Power supply outputs (also known as Zones) can control a maximum of 10 BlueBeam or
BlueDome fixtures installed in a single wire run.
To connect the installed fixture(s) to the power supply Output terminals:
Step 1:
Loosen the three “Output” screw terminals.
Step 2:
Strip each wire to .27" (6.9mm) and label them according to the system installation
wiring plan:
• GND typically uses black
• PWR typically uses red
• CTRL when used is typically violet
Step 3:
Terminate ground.
a: Terminate into the Output GND terminal.
b: Tighten the screw firmly onto the wire.
Step 4:
Terminate the power wire (typically red) into the PWR terminal and tighten the screw
firmly onto the wire.
Step 5:
Terminate the control wire (typically violet) into the CTRL terminal and tighten the screw
firmly onto the wire. When control is not required from the power supply, do not
terminate.
Step 6:
Reference
for instructions to terminate wiring at the
fixture.
.
Cable Specification
Output
Terminals
Wire
Torque
Notes
Power
30-12 AWG (.2-4mm2 solid or
.2-2.5mm2 stranded)
0.5 NM
Supports up to 10 fixtures per
output. For the one zone power
supply, the 10 fixtures can be
split between both outputs, or
utilize only one.
Ground
Control
OUTPUT 1
OUTPUT 2
PW
R
PW
R
G
N
D
G
N
D
CTRL
CTRL