background image

ETC Installation Guide

ColorSource

®

 PAR Pearl v1.7

Corporate Headquarters 

 Middleton, Wisconsin, USA 

 Tel +608 831 4116 

Service (Americas) 

 

[email protected] 

London, UK 

 Tel +44 (0)20 8896 1000 

 Service: (UK)

 [email protected] 

Rome, IT 

 Tel +39 (06) 32 111 683 

 Service: (UK)

 [email protected] 

Holzkirchen, DE 

 Tel +49 (80 24) 47 00-0 

 Service: (DE)

 [email protected] 

Hong Kong 

 Tel +852 2799 1220 

 Service: (Asia)

 [email protected]

Web:

 etcconnect.com 

 © 2018 Electronic Theatre Controls, Inc. 

 Product information and 

specifications subject to change. 

 ETC intends this document to be provided in its entirety. 

 US Patents 8,384,294 . 8,403,523 . 8,593,074 . 8,633,649 . 8,723,450 . 8,878,455 . 9,041,308 

 EU Patents 2638781 . 6020110157302 

 All other patents pending.

7412M2120-1.7 

 Rev A 

 Released 2018-04 

Overview

The ColorSource PAR Pearl is an affordable LED fixture that provides a bright, 
variable white light. 

The ColorSource PAR Pearl is UL924 listed as a Directly Controlled Luminaire 
for use in emergency lighting systems when used with the ETC DMX 
Emergency Bypass Controller (DEBC). 

   

Note:

Features described in this document require the latest 

version of software. For information on updating fixture 

software, see 

Updating the fixture software

 on 

page 12

.

Summary of Contents for ColorSource PAR Pearl

Page 1: ...ions subject to change ETC intends this document to be provided in its entirety US Patents 8 384 294 8 403 523 8 593 074 8 633 649 8 723 450 8 878 455 9 041 308 EU Patents 2638781 6020110157302 All other patents pending 7412M2120 1 7 Rev A Released 2018 04 Overview The ColorSource PAR Pearl is an affordable LED fixture that provides a bright variable white light The ColorSource PAR Pearl is UL924 ...

Page 2: ...ass Controller Equipment intended for this purpose must be properly selected installed and maintained so that facility conformance can be obtained Installation and servicing shall be performed by qualified service personnel IMPORTANT SAFEGUARDS When using electrical equipment basic safety precautions should always be followed including the following READ AND FOLLOW ALL SAFETY INSTRUCTIONS Do not u...

Page 3: ...sult breaker trip curves when used with other equipment Requires power from a non dimmable source Inrush 120V 35A first half cycle 240V 49A first half cycle Typical power consumption Note The ColorSource PAR Pearl is for indoor use only Note Maximum recommended ambient operating temperature Ta 40 C 104 F Maximum anticipated external surface temperature at 40 C ambient Tmax 80 C 176 F External temp...

Page 4: ...r stand yoke is available as an optional accessory Contact your local dealer for more information Safety cable The safety cable or other approved safety device must be attached to the fixture Attachment loops are provided on the rear of the fixture housing Take care to leave as little slack as possible in the safety cable to avoid catching the yoke of the fixture Connectors Power Two powerCON conn...

Page 5: ...dress See Setting the DMX address on page 6 2 Press the Mode button to access the Presets menu See Setting presets on page 10 Adjusting the tilt The fixture can be tilted up and down and rotated panned as needed 1 Loosen but do not remove the yoke locking knob 2 Tilt the fixture to the desired angle 3 Tighten the yoke locking knob User interface The user interface allows you to set the start addre...

Page 6: ...preset plays in the background and DMX data continues to take priority If DMX data is lost and a preset is active in the background the last selected preset automatically plays Setting the DMX address 1 Press any button to wake the display The display shows the DMX address 2 Use the Up and Down buttons to select the DMX address for the fixture You can also use RDM for DMX addressing See RDM values...

Page 7: ...olor temperature This is the default mode Direct emitter control intensity warm white cool white strobe 1 channel mode controls the intensity of preset 1 defaults to 3000K White 4 Press the Mode button to confirm your selection The display will automatically return to the DMX address after 10 seconds of inactivity and edits to the DMX control mode will not be saved This cancels unsaved changes DMX...

Page 8: ...105 106 2825 9 10 3550 58 4275 107 2850 11 3575 59 60 4300 108 109 2875 12 13 3600 61 62 4325 110 111 2900 14 15 3625 63 4350 112 2925 16 3650 64 65 4375 113 114 2950 17 18 3675 66 67 4400 115 116 2975 19 20 3700 68 69 4425 117 3000 21 3725 70 4450 118 119 3025 22 23 3750 71 72 4475 120 121 3050 24 25 3775 73 74 4500 122 3075 26 3800 75 4525 123 124 3100 27 28 3825 76 77 4550 125 126 3125 29 30 38...

Page 9: ...96 197 6150 233 234 5075 160 161 5625 198 6175 235 5100 162 163 5650 199 200 6200 236 237 5125 164 165 5675 201 202 6225 238 239 5150 166 5700 203 6250 240 5175 167 168 5725 204 205 6275 241 242 5200 169 170 5750 206 207 6300 243 244 5225 171 5775 208 6325 245 5250 172 173 5800 209 210 6350 246 247 5275 174 175 5825 211 212 6375 248 249 5300 176 5850 213 6400 250 5325 177 178 5875 214 215 6425 251...

Page 10: ... button for 3 seconds to confirm the preset selection The user interface will show a 3 second countdown The preset number blinks once to confirm that the preset has been recorded It is possible to activate a known preset from a connected fixture when DMX is not present If a connected fixture activates a preset that is not recognized by the fixture the fixture will hold its last look When DMX is re...

Page 11: ...ons to change the intensity level of the preset in real time 5 Press the Mode button to confirm your selection and return to the Presets menu The display will automatically return to the Presets menu after 10 seconds of inactivity and edits to the preset intensity will not be saved Locking the user interface After you have set up the fixture you can lock the user interface to prevent additional ch...

Page 12: ...d the Up and Down buttons simultaneously while restoring power 3 The display will show to indicate the update mode is selected 4 Press the Mode button to start the update process The display will alternate between and the percentage complete while updating The master fixture will reboot once the update is complete Restoring factory defaults Press and hold the Mode Up and Down buttons simultaneousl...

Page 13: ... ETC RDM values Manufacturer ID 0x6574 Electronic Theatre Controls Model ID 0x0203 ETC ColorSource PAR Pearl Parameter RDM PID Value DMX Start Address 0x00F0 Range 1 512 Personality ID 0x00E0 1 Variable Color Temp 2 Direct 3 1 Channel Output Frequency 0x8123 0 Standard 1 2 kHz 1 High 25 kHz ...

Page 14: ...ETC Installation Guide ColorSource PAR Pearl v1 7 ColorSource PAR Pearl v1 7 Page 14 of 16 ETC ...

Page 15: ...ETC Installation Guide ColorSource PAR Pearl v1 7 ColorSource PAR Pearl v1 7 Page 15 of 16 ETC ...

Page 16: ...ibration The fixture will need to be returned to the ETC factory contact your local dealer to set up a repair Screen toggles between and to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture has self cooled the error will automatically clear Screen toggles between and to indicate that the upgraded fixtures have a software issue R...

Reviews: