ETC Installation Guide
ColorSource CYC v1.7
Lock the User Interface
After you have set up the fixture, you can lock the user interface to prevent
additional changes.
1.
Press and hold the Up button and Down button simultaneously for
3 seconds. The display will show
Loc
to indicate that the user interface
is locked.
2.
To unlock the user interface, press and hold the Up button and Down
button simultaneously for 3 seconds.
Update the Fixture Software
ETC recommends using UpdaterAtor software to manage software updates.
For more information on UpdaterAtor, see the
UpdaterAtor Software Quick
Guide, which you can download for free from
.
When you add a ColorSource fixture running a newer software version or
update a ColorSource fixture to a newer software version using UpdaterAtor,
you can use that fixture to push the newer software version to all connected
ColorSource fixtures, except for ColorSource Spot jr fixtures. ColorSource
Spot jr fixtures can only update (and be updated by) other ColorSource Spot jr
fixtures.
1.
Remove power and DMX In from the master fixture that is running the
software version that you want to push to other fixtures.
2.
Press and hold the Up button and Down button simultaneously while
restoring power.
3.
The display will show
Udt rdy
to indicate the update mode is
selected.
4.
Press the Mode button to start the update process.
•
The display will alternate between
Udt
and the percentage
complete while updating.
•
The master fixture will reboot once the update is complete.
5.
Reconnect DMX In on the master fixture.
Restore Factory Defaults
Press and hold the Mode button, Up button, and Down button
simultaneously for 5 seconds. The DMX start address will blink once to
confirm that defaults have been restored.
Clean the Fixture
If necessary, clean the mirror and diffusion surface with a blast of oil-free air
or wipe with a clean, lint-free cloth. Isopropyl alcohol, distilled water, or a
50%-50% mixture of each can be used to clean the surface.
ColorSource CYC
Page 9 of 12
ETC