ETC Installation Guide
ColorSource CYC v1.7
Electrical
•
Operates between 100 V and 240 VAC at a frequency of 50/60 Hz.
•
Maximum power consumption is 160 W.
•
Up to 9 luminaires (15 A max) may be linked via power thru connector
(10 luminaires total per circuit) when used with an R20 Relay Module
or Unison Echo Relay Panel. Consult breaker trip curves when used
with other equipment. Requires power from a non-dimmable source.
•
Inrush:
-
120 V: 39 A (first half-cycle)
-
240 V: 74 A (first half-cycle)
Typical Power Consumption
100 V
120 V
230 V
Power
Current
Power
Current
Power
Current
Idle
1.66 W
0.04 A
1.38 W
0.04 A
1.18 W
0.05 A
Direct at Full
133.7 W
1.34 A
132.6 W
1.11 A
130.4 W
0.59 A
Safety cable
anchor point
Yoke
locking
knob
Washer
Installation
Mounting
The ColorSource CYC is
designed for floor mounting.
You can also use the yoke
accessory (included) for top-
hang pipe mounting with a
clamp. Use the included yoke
locking knobs and washers
(see image at right) to attach
the yoke accessory to the
fixture. Tilt the fixture so that
the base of the fixture is perpendicular to the cyclorama. See
Safety Cable
The safety cable (or other approved safety device) must be attached to the
fixture when it is mounted using the optional yoke and C-clamp (see image
above).
ColorSource CYC
Page 3 of 12
ETC