ETC Installation Guide
Pro One-Cell
Pro One-Cell
Page 17 of 29
ETC
D4 Series Driver Current Configuration
See
D4 Series Emergency Driver Current Configuration on page 22
for information on configuring
the driver current in D4 emergency drivers.
Note:
Do not change the switch settings on a D4 Constant Voltage (CV) model driver.
D4 Series Constant Current (CC) drivers can be configured for 400 mA or 600 mA output using the
four switch blocks shown in the illustration of the
Outputs
Each of the four switch blocks controls one output.
•
Switch block S1 controls LED1.
•
Switch block S2 controls LED2.
•
Switch block S3 controls LED3.
•
Switch block S4 controls LED4.
Switch Functions
Each switch block has six switches.
Note:
Do not change the switch 1 settings on a D4 Constant Voltage (CV) model driver.
•
Switch 1 sets the current output threshold.
ON = 400 mA, OFF = 600 mA.
•
Switches 2 through 5 control the DMX channel assigned to the output.
•
Switch 6 enables emergency functionality.
Switches 2 through 5 are factory set to allow each output to be controlled by an individual
DMX address. ETC recommends leaving the DMX channel switches (positions 2 through 5) at their
factory settings and using the ArcSystem Configuration Software or RDM settings to control the
behavior of each output.
Note:
ArcSystem D4 Drivers are factory configured for 600 mA output for compatibility
with ArcSystem Pro One-Cell and One-Cell Small luminaires. If you power a One-Cell or
One-Cell Small luminaire from a D4 output channel that is configured for 400 mA, the
output of the luminaire may be dim.
Note:
If you set an output on a non-emergency driver to emergency operation, the output
will remain at full (or their configured emergency behavior) because there is no
normal/sense input to the driver.