ETC ArcSystem Pro D4 Series Installation Manual Download Page 7

Introduction

1

Introduction

Congratulations on your purchase of ArcSystem products. ArcSystem is a family of overhead LED
products designed for installations where dimming, light quality, and ease of installation are
absolutely essential. With ArcSystem, you will experience perfectly smooth dimming from 100%
down to absolute zero. ArcSystem luminaires come in a variety of form factors, beam angles,
and color-temperature options, all with high-efficiency optics and an outstanding quality of light
ideal for any application.

ArcSystem products with ArcMesh can be controlled using wired DMX or the wireless ArcMesh
protocol. ArcSystem products without ArcMesh can be configured for RDM control. This manual
provides step by step instruction on the installation of ArcSystem Pro One-Cell luminaires, D4
Series Drivers, and full system integration. For information on installing ArcSystem Pro D1 and
D2 Series Drivers, see

the ArcSystem D1 and D2 Series Drivers Installation Guide

at

etcconnect.com/ArcSystem

For information on ArcSystem Pro Multi-Cell luminaires, see the

ArcSystem Pro Installation Manual

and the

ArcSystem Pro Multi-Cell RDM Installation Guide

at

etcconnect.com/ArcSystem

.

All ETC manuals are available for download free of charge at

etcconnect.com

.

Document Conventions

This document uses the following conventions to draw your attention to important information.

Note:

Notes are helpful hints and information that is supplemental to the main text.

CAUTION:

A Caution statement indicates situations where there may be

undefined or unwanted consequences of an action, potential for data loss or
an equipment problem.

WARNING:

A Warning statement indicates situations where damage may

occur, people may be harmed, or there are serious or dangerous
consequences of an action.

WARNING:

RISK OF ELECTRIC SHOCK! This warning statement indicates

situations where there is a risk of electric shock.

All ETC documents are available for free download from our website:

etcconnect.com

.

Please email comments about this manual to:

[email protected]

.

Summary of Contents for ArcSystem Pro D4 Series

Page 1: ...ArcSystem Pro D4 Series Drivers Installation Guide Part Number 7490M2170 Rev C Released 2020 12 ...

Page 2: ...rademarks and patents go to etcconnect com ip All other trademarks both marked and not marked are the property of their respective owners ETC intends this document whether printed or electronic to be provided in its entirety ...

Page 3: ...t Device 10 Site Survey for Wireless Installations 10 Installation Requirements 10 D4 Constant Voltage Drivers and Voltage Drop 11 One Cell Luminaire Installation 12 Preparing the Ceiling for Recessed Luminaires 12 Installing One Cell Recessed Luminaires 14 Installing One Cell Yoke Mounted Luminaires 14 D4 Series Wall Mount Driver Installation 15 Electrical and Wiring Specification 15 Wire and Ter...

Page 4: ... Output Channels 29 DMX In and DMX Thru 30 Emergency System One Cell Installation 31 Emergency Driver Power Input Wiring 31 Wall Mount Emergency Drivers 32 Wall Mount Emergency Driver Installation 34 Rack Mount Emergency Drivers 38 D4 Emergency Driver 150 Current Configuration 40 Final Installation and Operation 41 Power Up Procedure 41 Updating the Luminaire Firmware 41 Wireless ArcMesh Luminaire...

Page 5: ...nt Voltage Driver Output Channels 49 Voltage Drop 51 Wall Mount Bridging Kits 51 Rack Mount Bridging Kits 51 Output Channel Control Switches 52 Example Bridge Configurations 55 Bridging Procedure 58 Compliance 59 FCC Compliance 59 EU Declaration of Conformity 59 Table of Contents iii ...

Page 6: ...iv D4 Series Drivers Installation Guide ...

Page 7: ...cSystem D1 and D2 Series Drivers Installation Guide at etcconnect com ArcSystem For information on ArcSystem Pro Multi Cell luminaires see the ArcSystem Pro Installation Manual and the ArcSystem Pro Multi Cell RDM Installation Guide at etcconnect com ArcSystem All ETC manuals are available for download free of charge at etcconnect com Document Conventions This document uses the following conventio...

Page 8: ...number if you have called in previously Americas United Kingdom ETC Inc ETC Ltd Technical Services Department Technical Services Department 3031 Pleasant View Road 26 28 Victoria Industrial Estate Middleton WI 53562 Victoria Road 800 775 4382 USA toll free London W3 6UU England 1 608 831 4116 44 0 20 8896 1000 service etcconnect com techservltd etcconnect com Asia Germany ETC Asia ETC GmbH Technic...

Page 9: ... READ AND FOLLOW ALL SAFETY INSTRUCTIONS Do not use outdoors Do not let power supply cords touch hot surfaces Do not mount near gas or electric heaters Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition Do not use this e...

Page 10: ...ptions 19 24 37 60 ArcSystem Pro One Cell High Output external D1 HO driver required ideal for long throw 100 W full load power consumption fixed version recessed flush mount only adjustable version recessed flush mount with two axis tip and tilt yoke mount version with single axis tilt beam angle options 18 30 50 ArcSystem Pro One Cell Micro external D2 driver required ideal for short medium thro...

Page 11: ...ies D2 Series and D4 Series Drivers D1 Driver D1 HO Driver D2 Driver Wall Mount D4 Driver 150 also available in 350 and 700 models Rack Mount D4 Driver 350 also available in 700 model Note Antenna is not present on RDM models ...

Page 12: ... Micro and ArcSystem Pro One Cell standard luminaires are not interchangeable One Cell Micro luminaires require a D2 driver to function One Cell and One Cell Small luminaires require a D1 driver or D4 driver to function Note All ArcSystem wireless luminaires require a TX1 Transmitter and commissioning tool to set DMX addresses for both wired DMX and wireless installations Contact your ETC Service ...

Page 13: ...aire TX1 Transmitter and a wired DMX console for the main control source AC Power 100 240 VAC Active DMX output for other wired devices DMX512 from Lighting Control AUX Input Toggle Operation DMX out DMX in Wireless Luminaire TX1 Transmitter Each system requires a minimum of one TX1 Transmitter The TX1 is used as a transmitter of wireless data to luminaires or other devices within a system Note By...

Page 14: ...minaires as possible to avoid unnecessary traffic on the network and possible system performance issues Emergency System Overview ArcSystem drivers and luminaires can be purchased in UL924 listed variants Each of the luminaires can be configured to be UL924 listed when wired into an existing emergency response system See Emergency System One Cell Installation on page 31 Install the luminaire and A...

Page 15: ...e will not be available until the sense input has been restored WARNING Do not mix 120 V and 277 V between the sense and emergency feeds AVERTISSEMENT Ne pas inverser les alimentations à 120 V et 277 V entre les alimentations de détection et de secours WARNING Sense normal and Maintained normal emergency feeds must have the same phase The diagram below shows the recommended installation AVERTISSEM...

Page 16: ...o this equipment Any work must comply with OSHA Safe Working Practices WARNING Circuits that are installed without an accessible power disconnect device cannot be serviced or operated safely AVERTISSEMENT Il est imprudent d utiliser ou de réparer les circuits installés sans qu un dispositif de déconnexion de l alimentation ne soit accessible Site Survey for Wireless Installations ArcSystem transmi...

Page 17: ...ccess the wiring area of the rack should only be accessible with the use of a tool D4 Wall Mount Driver Wall mounted D4 drivers require 7 6 cm 3 in clearance around the side vents for proper ventilation D4 Constant Voltage Drivers and Voltage Drop Consult the manufacturer s documentation for your load to find the minimum voltage required for operation Voltage drop calculations vary by project and ...

Page 18: ...p anchors Cut the hole larger than the minimum hole diameter listed below and smaller than the luminaire s outer bezel The images below provide an example of the bezels on the Pro One Cell luminaires Luminaire Minimum Hole Diameter Pro One Cell 16 5 cm 6 1 2 in Pro One Cell High Output 17 0 cm 6 11 16 in Pro One Cell Small 9 5 cm 3 3 4 in Pro One Cell Micro 7 6 cm 3 in Note If you are installing t...

Page 19: ...lation 13 Pro One Cell fixed model Pro One Cell adjustable model A A B B Pro One Cell Small adjustable model A B Pro One Cell High Output adjustable model A B Pro One Cell Micro adjustable model A B A Outer bezel B Inner bezel ...

Page 20: ...SPOSITIF ÉLECTRONIQUE DE PUISSANCE WARNING Adjustable ArcSystem Pro One Cell fixtures and adjustable ArcSystem Pro One Cell Small fixtures are suitable for Non Fire Rated installations ONLY AVERTISSEMENT Les lampes Pro One Cell ArcSystem réglables et Pro One Cell Small ArcSystem réglables sont parfaites UNIQUEMENT pour les installations sans indice de résistance au feu Note Make sure that the flex...

Page 21: ...t an accessible power disconnect device cannot be serviced or operated safely AVERTISSEMENT Il est imprudent d utiliser ou de réparer les circuits installés sans qu un dispositif de déconnexion de l alimentation ne soit accessible Install the D4 Driver on a power distribution system with reliably identified earthed neutral and install a maximum 15 A circuit breaker on the line conductor ETC recomm...

Page 22: ...26 14 AWG using the provided two terminal connectors Follow Class 1 wiring methods 6 mm 1 4 in 0 4 0 5 Nm 3 5 4 4 in lb D4 Driver 150 standard and emergency models with molex connectors Follow class 2 wiring methods D4 Driver 350 and 700 standard and emergency models 0 5 6 mm2 22 10 AWG solid or stranded Follow Class 1 wiring methods 10 12 mm 3 8 1 2 in none DMX In Thru RJ45 Connectors Cat5e or be...

Page 23: ...d installation location and mark then pre drill the four mounting holes Note Vents on back of driver must not make contact with the wall for proper airflow 3 Install wall anchors as needed 4 Align the driver to the mounting location and install the mounting hardware Secure the hardware 5 Install conduit hardware as required for your installation wire plan D4 Driver 150 wall mount drivers Remove th...

Page 24: ...o the luminaire from the driver If you are installing emergency system drivers Emergency System One Cell Installation on page 31 Wall Mount Driver Wiring Overview Output type varies by model A B C S1 S2 S3 S4 LED1 LED2 LED3 LED4 Switch blocks D4 Driver 150 A Constant Current with Molex connectors B Constant Current with terminal outputs C Constant Voltage with terminal outputs ...

Page 25: ...E C A B D E D4 Driver 350 D4 Driver 700 A Power input B Output channels C Antenna D DMX input and thru RJ45 E DMX input and thru eight pin terminal blocks The antenna is not present on RDM models Eight pin terminal blocks are not present on D4 Driver 150 ...

Page 26: ...rminated by a qualified electrician and should follow standard wiring installation practices 1 Make sure power is off at the main circuit breaker 2 See Wire and Terminal Specifications on page 16 for specification of wire strip length and terminal torque ratings Prepare the wires accordingly 3 Loosen the three screw terminals for NEUTRAL N GROUND and LINE L connections 4 Insert the ground wire typ...

Page 27: ...rminal B tool slot square To install wire insert the wire into the terminal To remove wire insert a 3 5 mm flatblade screwdriver into the tool slot next to the wire terminal to release the wire then pull the wire out of the terminal Wall Mount D4 Driver 350 and 700 Power Input Detail Factory Wire Colors Model Color Type North America and Europe green yellow ground earth North America black line ho...

Page 28: ...in Note Power wiring should only be installed and terminated by a qualified electrician and should follow standard wiring installation practices 1 Install the ceiling with the prepared mounting hole for the luminaire 2 Run the luminaire cable through the previously installed screw clamp conduit connector at one of the driver knockouts Two pin terminal wiring Line Neutral Line Neutral Line Neutral ...

Page 29: ...out Information Pin Description 1 Data 2 Data 7 8 ISO ground common RJ45 DMX Termination All models of D4 Driver have RJ45 receptacles for DMX In and Thru ETC recommends Cat5e or better minimum 0 2 mm2 24 AWG conductors terminated to T568B standard The DMX In and Thru RJ45 connectors on the wall mount D4 Driver 350 and 700 are not labeled and are interchangeable Their locations are shown below Det...

Page 30: ...d wire from each pair and apply a piece of 1 6 mm 1 16 in clear heat shrink to each shield wire 6 Twist each shield wire back onto its data pair and then apply a 4 cm 1 5 in piece of 0 5 cm 3 16 in heat shrink all the way down each 3 wire set Make sure to capture the foil shielding at the base 7 Apply the 5 cm 2 in piece of the 1 cm 3 8 in heat shrink centered on the end of the cable jacket and th...

Page 31: ...Data Black From DMX source If daisy chaining to another rack or DMX device The graphic on the left illustrates DMX In and Thru termination using screw terminal connectors intended for use with Belden 9729 cable or equivalent Screw terminal connectors are supplied in the DMX Preparation Kit w Screw Connector part number 4100A1012 and shipped with your ArcSystem Pro product Cable other than Belden 9...

Page 32: ...n a D4 Constant Voltage CV model driver Switch 1 sets the current output threshold ON 400 mA OFF 600 mA Switches 2 through 5 control the DMX channel assigned to the output Switch 6 enables emergency functionality Switches 2 through 5 are factory set to allow each output to be controlled by an individual DMX address ETC recommends leaving the DMX channel switches positions 2 through 5 at their fact...

Page 33: ...Wire and terminal specifications are the same for all rack mount drivers Wire and Terminal Specifications Terminal Connector Wire Range Specification Strip Length Torque Rating 100 240 V Power Input power cord s provided standard models not applicable emergency models may depend on installation 24 V Power Output four two position screw terminal connectors provided 0 2 4 mm2 24 12 AWG Follow Class ...

Page 34: ...ck using the included ETC rack mount hardware Mount in a horizontal orientation to ensure even mechanical loading in the rack avoiding hazardous or dangerous loading conditions Circuit Overloading When installing the D4 Driver in an equipment rack consider the connection of the equipment to the rack or power source to avoid overloading the rack circuit or supply wiring Consider the rack or power d...

Page 35: ...nduit from the fixture to the rack and route it to the D4 Driver output terminals Output channels are labeled CH1 CH2 CH3 CH4 b Loosen the terminal screws on the provided two position screw terminal plug c Terminate the neutral wire to the terminal securing the terminal screw onto the wire d Terminate the line hot wire to the terminal securing each terminal screw onto the wire e Tug gently on the ...

Page 36: ...air of wires data data plus an ISO ground common Terminate DMX In and Thru ETC recommends Cat5e or better minimum 0 2 mm2 24 AWG conductors terminated to T568B standard Note D4 drivers are not self terminating You must terminate the last driver in line with a DMX terminator plug in the RJ45 Thru receptacle To purchase an RJ45 terminator please contact your ETC customer service representative and r...

Page 37: ...n on page 27 Emergency Driver Power Input Wiring D4 Emergency Drivers are available for systems requiring emergency lighting control Note The installation must conform to local and national codes D4 Emergency Drivers require two branch circuit power input connections normal sense and maintained emergency Maintained emergency provides constant power to the D4 Driver regardless of the state enforcin...

Page 38: ...Emergency Drivers Output type varies by model A B C S1 S2 S3 S4 LED1 LED2 LED3 LED4 Switch blocks SENSE SENSE D4 Emergency Driver A Constant Current with Molex connectors B Constant Current with terminal outputs C Constant Voltage with terminal outputs ...

Page 39: ... D4 Emergency Driver 700 A Maintain emergency power input B Sense normal sense power input C Output channels D Antenna E DMX input and thru RJ45 F DMX input and thru eight pin terminal blocks The antenna is not present on RDM models Eight pin terminal blocks are not present on D4 Driver 150 ...

Page 40: ...es Hors tension avant d ouvrir With the exception of power input terminations Wall Mount D4 Emergency Driver installation requirements are the same as those of the standard Wall Mount D4 Driver Complete the installation as follows referencing these sections for installation details Review Prepare for Wall Mount Installation on page 17 Review Electrical and Wiring Specification on page 15 Complete ...

Page 41: ...hould follow standard wiring installation practices D4 Emergency Driver 150 Connect the mains sense input to a normal branch circuit See Factory Wire Colors at D4 Driver 150 on page 20 1 Make sure power is off at the main circuit breaker 2 Loosen the three screw terminals for NEUTRAL N GROUND and LINE L connections 3 Insert the ground wire typically green into the GROUND terminal and tighten the s...

Page 42: ...epare the wires accordingly 3 See Push In Terminal Blocks on page 21 for general instructions on using the push in terminal blocks 4 Insert the ground wire typically green into the terminal marked Sense 5 Insert the neutral wire typically white into the terminal marked Sense N 6 Terminate the line hot wire typically black into theterminal marked Sense L 7 Tug gently on the wires to ensure they are...

Page 43: ...0 Sense and Maintained Input Detail Factory Wire Colors Model Color Type North America and Europe green yellow ground earth North America black line hot North America white neutral Europe brown live Europe blue neutral 1 Make sure power is off at the main circuit breaker 2 See Wire and Terminal Specifications on page 16 for specification of wire size and strip length Prepare the wires accordingly ...

Page 44: ...Rack Mount D4 Emergency Driver 350 A B C D E F G H A B C D E F G Rack Mount D4 Emergency Driver 700 A Output channel CH 1 E DMX In B Output channel CH 2 F DMX Thru C Output channel CH 3 G Maintained power input cord bare end D Output channel CH 4 H Normal Sense power input cord bare end ...

Page 45: ... have hard wired power input cables with plugs Rack mount D4 Emergency Drivers sold outside of North America have hard wired power input cables with bare ends for direct connection to your maintained emergency and normal sense power supplies The cables are labeled near the strain reliefs for Maintained Input and Sense Input With the exception of power input terminations rack mount D4 Emergency Dri...

Page 46: ...h Functions Each switch block has six switches Note Do not change the switch 1 settings on a D4 Constant Voltage CV model driver Switch 1 sets the current output threshold ON 400 mA OFF 600 mA Switches 2 through 5 control the DMX channel assigned to the output Switch 6 enables emergency functionality Switches 2 through 5 are factory set to allow each output to be controlled by an individual DMX ad...

Page 47: ...o date upgrade it following the instructions at Updating the Luminaire Firmware below Note All ArcSystem luminaires are factory set to provide 100 output level This allows an electrical contractor to check that all products are properly installed and wired During system commissioning the certified ETC technician will remove this setting and configure DMX addresses for normal use During normal use ...

Page 48: ... available for free download at etcconnect com Concert ArcSystem is compliant with DMX 512 A ANSI E1 11 2008 R2013 DMX loss behavior is hold last look For wired DMX installation each luminaire can be addressed to any one of the 512 DMX addresses up to the maximum device limit of 32 devices on each DMX line Wireless DMX control requires a TX1 Transmitter and luminaires with the wireless ArcMesh tra...

Page 49: ...e the ArcSystem comissioning tool software to add DMX fixtures RDM Values Manufacturer ID 0x6574 Electronic Theatre Controls Model IDs Product Type Description Model ID ArcSystem D4 Drivers Constant Current D4 Driver 150 0x1204 Constant Current D4 Emergency Driver150 0x1304 Constant Voltage D4 Driver 150 D4 Driver 350 and D4 Driver 700 wall mount and rack mount 0x1205 Constant Voltage D4 Emergency...

Page 50: ... Curve aka D04A Set to 2 is Linear Set to 3 is Square Law Curve Description 0x0344 Get returns an ASCII text string Output Response Time 0x0345 0x01 1000 ms 100 steps 0x02 900 ms 90 steps 0x03 800 ms 80 steps 0x04 700 ms 70 steps 0x05 600 ms 60 steps 0x06 500 ms 50 steps 0x07 400 ms 40 steps 0x08 300 ms 30 steps 0x09 250 ms 25 steps 0x0A 200 ms 20 steps 0x0B 100 ms 10 steps 0x0C 50 ms 5 steps 0x0D...

Page 51: ...d safely AVERTISSEMENT Il est imprudent d utiliser ou de réparer les circuits installés sans qu un dispositif de déconnexion de l alimentation ne soit accessible WARNING RISK OF ELECTRIC SHOCK The light sources in this luminaire are not user replaceable and must be replaced only by a qualified technician Contact ETC Customer Support for assistance AVERTISSEMENT RISQUE DE DÉCHARGE ÉLÉCTRIQUE Les so...

Page 52: ...ystem modification could result in serious injury or death AVERTISSEMENT RISQUE DE MORT PAR DÉCHARGE ÉLECTRIQUE Négliger de débrancher toutes les sources d alimentation du système avant l installation l entretien le nettoyage ou toute autre modification du système peut causer des blessures graves ou la mort De energize main feed to ArcSystem and follow appropriate Lockout Tagout procedures as mand...

Page 53: ... Solid On wireless operation active DMX signal is being received Solid On wired DMX DMX is present Status Steady blinking processor is operating normally Solid On system is responding to DMX instruction Solid On when no DMX command is being sent there is a processor fault Contact ETC Technical Services for assistance Channel OK LEDs Solid On with no Channel Limit LEDs lit channel is outputting nor...

Page 54: ...lternate flashing if the current drawn on any output channel exceeds the trip limits Channel Limit LEDs will turn off and Channel OK LEDs will turn solid on when the circuit reconnects Warning Limits and Trip Limits Driver Description Warning Limits Trip Limits Single Channel Number of Channels Per Bridge Single Channel Number of Channels Per Bridge 2 3 4 2 3 4 D4 Driver 150 or D4 Emergency Driver...

Page 55: ...4DERDM350CV24R ARCD4D350CV24W ARCD4DE350CV24W ARCD4DRMD350CV24W ARCD4DERDM350CV24W ARCD4D700CV24R ARCD4DE700CV24R ARCD4DRDM700CV24R ARCD4DERDM700CV24R ARCD4D700CV24W ARCD4DE700CV24W ARCD4DRDM700CV24W ARCD4DERDM700CV24W WARNING RISK OF DEATH BY ELECTRIC SHOCK Before you begin pulling and terminating wire to the ArcSystem Driver enclosure or TX1 Transmitter make sure the main circuit breaker cabinet...

Page 56: ...ergency Driver 150 2 bridged into 1 2 2 A 53 W 3 bridged into 1 3 4 A 79 W 4 bridged into 1 4 4 A 110 W Wall Mount D4 Driver 350 or D4 Emergency Driver 350 2 bridged into 1 5 8 A 139 W 3 bridged into 1 8 25 A 198 W 4 bridged into 1 11 A 264 W Rack Mount D4 Driver 350 or D4 Emergency Driver 350 2 bridged into 1 5 6 A 134 W 3 bridged into 1 8 6 A 206 W 4 bridged into 1 11 A 264 W Wall Mount D4 Drive...

Page 57: ...for D4 Driver 350 and D4 Emergency Driver 350 for bridging combinations of 2 3 or 4 channels two 3 position WAGO connectors each with two attached black wires terminated with forks one 5 position WAGO connector with four attached black wires terminated with forks 3 7490K2004 bridging kit for D4 Driver 700 or D4 Emergency Driver 700 for bridging combinations of 2 channels two 3 position WAGO connec...

Page 58: ...individual control of each output In order to bridge channels together you must adjust the positions of switches 2 5 LED 1 LED 2 LED 3 LED 4 S1 S2 S3 S4 Switch blocks CH 1 CH 2 CH 3 CH 4 S1 S2 S3 S4 Switch blocks S1 S2 S3 S4 Wall Mount D4 Driver 150 Wall Mount D4 Driver 350 Wall Mount D4 Driver 700 S1 S2 S3 S4 CH 1 CH 2 CH 3 CH 4 S1 S2 S3 S4 Switch blocks Rack Mount D4 Driver 350 Rack Mount D4 Dri...

Page 59: ...ositions 1 and 6 are factory set and should not be adjusted Switch positions 2 through 5 are factory set to allow each output to be controlled individually You must adjust these switches on the switch block that controls each output channel that you want to bridge D4 Driver 150 Factory Settings for Individual Output Channel Control Switch Block Output Switch Positions 1 2 3 4 5 6 S1 LED 1 Do not a...

Page 60: ...els that are electrically connected bridged with different switch settings may have reduced capcacity Note If you are using a wireless D4 Driver with ArcMesh you must also set bridged outputs to the same DMX address in the ArcSystem Configuration Software so that they function as one output channel All output channels with the same settings on switch positions 2 5 will respond to the same DMX addr...

Page 61: ...unt D4 Driver 350 Rack Mount D4 Driver 350 Note Do not bridge three or four output channels into one output channel on a D4 Driver 700 D4 Driver 150 Switch Settings for Four Output Channels Bridged into One Switch Block Output Switch Positions 1 2 3 4 5 6 S1 LED 1 Do not adjust from factory setting ON OFF OFF OFF Do not adjust from factory setting S2 LED 2 ON OFF OFF OFF S3 LED 3 ON OFF OFF OFF S4...

Page 62: ...output channels bridged in pairs CH1 CH2 CH3 CH4 Wall Mount D4 Driver 150 Wall Mount D4 Driver 350 Wall Mount D4 Driver 700 Rack Mount D4 Driver 350 Rack Mount D4 Driver 700 D4 Driver 150 Switch Settings for Output Channels Bridged in Pairs Switch Block Output Switch Positions 1 2 3 4 5 6 S1 LED 1 Do not adjust from factory setting ON OFF OFF OFF Do not adjust from factory setting S2 LED 2 ON OFF ...

Page 63: ...d into one CH1 CH2 CH3 CH4 Wall Mount D4 Driver 150 Wall Mount D4 Driver 350 Rack Mount D4 Driver 350 Note Do not bridge three or four output channels into one output channel on a D4 Driver 700 D4 Driver 150 Switch Settings for Three Output Channels Bridged into One Switch Block Output Switch Positions 1 2 3 4 5 6 S1 LED 1 Do not adjust from factory setting ON OFF OFF OFF Do not adjust from factor...

Page 64: ...l Control Switches on page 52 e Replace the cover on the rack mount D4 Driver and reinstall the driver in the equipment rack 2 Choose a WAGO connector from the bridging kit with at least one more position than the number of channels to be bridged 3 Bus the negative poles of the output channel connectors Outputs are labeled labeled LED 1 LED 2 LED 3 and LED 4 D4 Driver 150 or CH 1 CH 2 CH 3 and CH ...

Page 65: ...rovide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in ...

Page 66: ...60 D4 Series Drivers Installation Guide ...

Page 67: ...Compliance 61 ...

Page 68: ... 683 Hong Kong 852 2799 1220 Paris FR 33 1 4243 3535 Web etcconnect com Support support etcconnect com Contact etcconnect com contactETC 2020 ETC Trademark and patent info etcconnect com ip Product information and specifications subject to change ETC intends this document to be provided in its entirety 7490M2170 Rev C Released 2020 12 ...

Reviews: