background image

ETC Installation Guide

D1 & D2 Series Drivers

D1 & D2 Series Drivers

Page 23 of 25

ETC

Updating the Luminaire Firmware

When commissioning a system installation, check all ArcSystem drivers and multi-cell luminaires to
ensure that the latest firmware is present. If the firmware is not up to date, upgrade it following the
instructions below for your luminaire type.

Wireless ArcMesh Luminaires

Upgrade luminaire firmware using the ArcSystem Configuration Software. The fixture firmware file
and ArcSystem Configuration Software are available for free at

etcconnect.com

.

RDM Luminaires

Upgrade luminaire firmware using ETC Concert and ETC UpdaterAtor software before
commissioning is completed. For more information on UpdaterAtor, download the

UpdaterAtor

Software Quick Guide

for free at

etcconnect.com

.

Commissioning a Wireless ArcSystem

Initial programming of a wireless ArcSystem requires a USB commissioning tool (ARC-CT), and
existing hardware such as a laptop or desk top computer that is connected to ArcSystem. This
programming will be carried out by an ETC certified technician at the time of system commissioning
and training.

The following is a list of procedures included in the configuration process:

patching groups of luminaires to specific DMX channels

assigning minimum and maximum dimming levels per group

assigning power fail/recovery options per group

Maintenance

WARNING:

RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all

power to the system before installation, maintenance, cleaning, or any other
system modification could result in serious injury or death.

AVERTISSEMENT :

RISQUE DE MORT PAR DÉCHARGE ÉLECTRIQUE! Négliger

de débrancher toutes les sources d’alimentation du système avant l’installation,
l’entretien, le nettoyage ou toute autre modification du système peut causer
des blessures graves ou la mort.

De-energize main feed to ArcSystem and follow appropriate Lockout/Tagout
procedures as mandated by NFPA 70E. It is important to note that electrical
equipment such as breaker panels can present an arc flash hazard if improperly
serviced. This is due to the high amounts of short-circuit current available on
the electrical supply to this equipment. Any work must comply with OSHA Safe
Working Practices.

WARNING:

Circuits that are installed without an accessible power disconnect

device cannot be serviced or operated safely.

AVERTISSEMENT :

Il est imprudent d'utiliser ou de réparer les circuits

installés sans qu'un dispositif de déconnexion de l'alimentation ne soit
accessible.

Summary of Contents for ArcSystem Pro D1 HO

Page 1: ...l ArcSystem products without ArcMesh can be configured for RDM control This manual provides step by step instruction on the installation of ArcSystem Pro One Cell luminaires D1 and D2 Series Drivers a...

Page 2: ...is tilt beam angle options 19 24 37 60 ArcSystem Pro One Cell High Output external D1 HO driver required ideal for long throw 100 W full load power consumption fixed version recessed flush mount only...

Page 3: ...MX control The D1 Driver provides up to 25 W to a single One Cell or One Cell Small luminaire The D1 HO Driver provides up to 100 W to a single One Cell High Output luminaire The D2 Driver supports on...

Page 4: ...nsmitter with the highest MAC address acts as a master with the others assuming the role of backup For information on installing the ArcSystem TX1 Transmitter for use with ArcMesh installations see th...

Page 5: ...all signal level of the system CAUTION If re broadcast mode is required use this feature in as few luminaires as possible to avoid unnecessary traffic on the network and possible system performance is...

Page 6: ...input has been restored WARNING Do not mix 120 V and 277 V between the sense and emergency feeds AVERTISSEMENT Ne pas inverser les alimentations 120 V et 277 V entre les alimentations de d tection et...

Page 7: ...readily accessible input power disconnect device installed ahead of your ArcSystem products WARNING RISK OF DEATH BY ELECTRIC SHOCK Failure to disconnect all power to the system before installation m...

Page 8: ...luminaires or drivers temporarily or permanently may cause damage to the luminaires or drivers Preparing the Ceiling for Recessed Luminaires This section is specific to the recessed flush mounted vari...

Page 9: ...Cell High Output luminaires plan the luminaire and driver locations around the required spacing listed below Install with minimum spacings between a Center to center of adjacent luminaires 609 6 mm 24...

Page 10: ...tibles ou une isolation thermique NE PAS INSTALLER D ISOLATION MOINS DE 76 mm 3 po DE TOUTE PARTIE DE LA LAMPE OU DU DRIVER DISPOSITIF LECTRONIQUE DE PUISSANCE WARNING Adjustable ArcSystem Pro One Cel...

Page 11: ...ne of DMX The following illustration shows an example of a linear ceiling installation with one luminaire for each D1 Series driver The cable between an ArcSystem Pro One Cell Series luminaire and its...

Page 12: ...sible Wire and Terminal Specifications Terminal Connector Conduit Entry Wire Range Specifications Strip Length Torque Rating D1 power input line neutral ground in conduit Up to 6 mm2 10 AWG solid or s...

Page 13: ...Driver Wiring of the driver consists of wiring power and data DMX to the driver for your luminaire and then running power out to the luminaire from the driver If you are installing emergency system dr...

Page 14: ...l and tighten the screw 5 Insert the neutral wire typically white into the NEUTRAL N terminal and tighten the screw 6 Insert the line wire typically black into the LINE L terminal and tighten the scre...

Page 15: ...res Data and Data plus an ISO ground common ETC recommends Cat5e or better minimum 24 AWG conductors terminated to T568B standard Up to 32 D1 D2 or D4 series drivers can be connected per DMX run DMX C...

Page 16: ...duit to the driver There are four conduit knockouts available 5 Install Romex or nonmetallic screw clamp conduit connectors to output knockouts as needed Note Make sure that the flexible electrical su...

Page 17: ...ETC Installation Guide D1 D2 Series Drivers D1 D2 Series Drivers Page 17 of 25 ETC Wiring D1 and D2 Series Emergency Drivers D1 Emergency Driver D1 HO Emergency Driver D2 Emergency Driver...

Page 18: ...N terminal and tighten the screw 5 Connect the line wire typically black into the LINE L terminal and tighten the screw 6 Tug gently on the wires to ensure they are secure Connect Maintained Input Co...

Page 19: ...ransmitter within the same plane as the luminaires Dual Redundancy Operation TX1 transmitters can be set up with dual redundancy allowing a backup transmitter to take control if the master transmitter...

Page 20: ...ired DMX or a hybrid of the two making it a great solution for both new construction and retrofit situations ArcSystem RDM Systems can be controlled over wired DMX from a lighting console or ETC Conce...

Page 21: ...DMX output from the TX1 you must use the ArcSystem comissioning tool software to add DMX fixtures RDM Values Manufacturer ID 0x6574 Electronic Theatre Controls Model IDs Product Type Description Mode...

Page 22: ...Description 0x0344 Get returns an ASCII text string Output Response Time 0x0345 0x01 1000 ms 100 steps 0x02 900 ms 90 steps 0x03 800 ms 80 steps 0x04 700 ms 70 steps 0x05 600 ms 60 steps 0x06 500 ms...

Page 23: ...of procedures included in the configuration process patching groups of luminaires to specific DMX channels assigning minimum and maximum dimming levels per group assigning power fail recovery options...

Page 24: ...l components can be cleaned using compressed oil free air as described above or a clean micro fiber cloth The use of any liquid cleaning solution is not recommended Inspect all mounting hardware for w...

Page 25: ...t may cause undesired operation ArcSystem wireless products contain FCC ID for US TYOJN5168M5 and Industry Canada IC ID IC 7438A CYO5168M5 Note Wireless capable ArcSystem products have been tested and...

Reviews: