Summary of Contents for ArcSystem Navis 100

Page 1: ...ArcSystem Navis 100 Installation Guide Part Number 7496M2100 Rev A Released 2020 03 ...

Page 2: ...rademarks and patents go to etcconnect com ip All other trademarks both marked and not marked are the property of their respective owners ETC intends this document whether printed or electronic to be provided in its entirety ...

Page 3: ...ures 4 Channel Settings for RGBW Luminaires 5 Before You Begin Installation 6 Power Disconnect Device 6 Installation Requirements 6 Wiring the Luminaires 6 RJ45 Pinout Information 7 Use of Third Party Drivers with Daisy Chained Luminaires 8 Installation 9 Prepare the Ceiling 10 Spacing for Wall Wash Luminaires 10 Install a Luminaire 11 Install a Wall Wash Luminaire 13 ...

Page 4: ...est 16 Update RGBW Luminaire Firmware 16 RGBW Luminaire DMX Personalities 17 Install Replacement Lens 18 Install Replacement Secondary Optic 20 Maintenance 21 Specifications 21 Accessories 22 Compliance 23 FCC Part 15 Class A 23 ii Navis 100 Installation Guide ...

Page 5: ... your attention to important information Note Notes are helpful hints and information that is supplemental to the main text CAUTION A Caution statement indicates situations where there may be undefined or unwanted consequences of an action potential for data loss or an equipment problem WARNING A Warning statement indicates situations where damage may occur people may be harmed or there are seriou...

Page 6: ...mber if you have called in previously Americas United Kingdom ETC Inc ETC Ltd Technical Services Department Technical Services Department 3031 Pleasant View Road 26 28 Victoria Industrial Estate Middleton WI 53562 Victoria Road 800 775 4382 USA toll free London W3 6UU England 1 608 831 4116 44 0 20 8896 1000 service etcconnect com techservltd etcconnect com Asia Germany ETC Asia ETC GmbH Technical...

Page 7: ... Peut être nocif pour les yeux Note The light source in this luminaire is not replaceable When the light source reaches its end of life replace the entire luminaire Contact ETC Customer Support for assistance IMPORTANT SAFEGUARDS When using electrical equipment basic safety precautions should always be followed including the following READ AND FOLLOW ALL SAFETY INSTRUCTIONS Do not use the luminair...

Page 8: ... and their height is the responsibility of the specifier and installer in order to achieve the minimum FC levels of NFPA101 Installation scenarios should be evaluated by the AHJ to confirm illuminance and performance requirements of ANSI NFPA 101 and the IBC Note Installation must follow all national and local codes for electrical equipment Navis 100 Features 4 2 3 1 4 5 1 In Port 2 Out Port 3 Cha...

Page 9: ...nt from the control source on the channel to which the luminaire is assigned See the RDM information in the installation manual for your F Drive series driver for information about configuring control channels To set the channel on an RGBW luminaire use a small flatblade screwdriver to turn the rotary switch so that it points to the channel number that you want to assign to the luminaire Note If R...

Page 10: ...turns off if the operating temperature exceeds the maximum temperature Dry locations only IP20 rated Suitable for use in air handling spaces Installation location must support the weight of the luminaire and applicable mounting hardware Navis 100 RGBW luminaires require 0 31 m 12 in minimum spacing for the following center to center of adjacent luminaires center of luminaire to side building membe...

Page 11: ...previous luminaire in line These pins pass through power to the next luminaires in line Out Port Pin Description 1 5 THRU 1 2 6 THRU 2 3 7 THRU 3 4 8 No Connection Note Navis 100 RGBW luminaires are not self terminating You must terminate the last luminaire in line with a 120Ω resistor An RJ45 terminator is included with each F Drive series Chroma Card To purchase extra RJ45 terminators please con...

Page 12: ...stant Current CC and Fade to Warm drivers natively support this wiring configuration Channel Input Pins for First Fixture in Daisy Chain Description 1 first fixture 1 Ground Earth 5 Constant current White 600 mA maximum Fade to Warm 450 mA maximum 2 second fixture 2 Ground Earth 6 Constant current White 600 mA maximum Fade to Warm 450 mA maximum 3 third fixture 3 Ground Earth 7 Constant current Wh...

Page 13: ...és NON IC ils ne conviennent donc PAS pour une installation en contact direct avec des matières combustibles ou une isolation thermique NE PAS INSTALLER D ISOLATION À MOINS DE 76 mm 3 po DE TOUTE PARTIE DE LA LAMPE WARNING The luminaire must be installed at least 0 1 m 4 0 in away from all lighted objects AVERTISSEMENT Le luminaire doit être installé à au moins 0 1 m 4 0 po de tout objet allumé CA...

Page 14: ...here is sufficient cable extending down through the ceiling opening so that the luminaire can be inspected and serviced when needed ETC recommends at least 50 cm 20 in of cable Spacing for Wall Wash Luminaires If you are installing luminaires with a wall wash trim plate ETC recommends that you allow minimum spacing as follows to obtain the best coverage 61 cm 2 ft between the wall and the center o...

Page 15: ...rface 1 Remove the magnetic trim plate from the base of the luminaire to expose the ceiling clamp screws and the locking screw 2 If necessary install the secondary optic the finishing ring or both by snapping the part into the lens holder Note The edges of the secondary optic and the finishing ring may protrude below the edge of the trim plate when you tilt the luminaire to its full extent 3 If in...

Page 16: ...onnections will result in improper operation of the luminaires If you are installing RGBW luminaires you must terminate the last luminaire in the line See Wiring the Luminaires on page 6 for details 6 Insert the luminaire through the hole in the ceiling If necessary rotate the luminaire so that the tilt and rotation of the luminaire are oriented appropriately 7 Using a 2 0 mm hex key tighten the s...

Page 17: ...ing an RGBW luminaire wall wash you must attach spacer pads to the wall wash angle template and set the channel for the RGBW luminaire a Affix the three provided spacer pads to the back edge of the wall wash angle template adjacent to the three notches Note Do not attach the spacer pads to the wall wash angle template if you are installing a White or Fade to Warm wall wash luminaire b Use a small ...

Page 18: ...re installing RGBW luminaires you must terminate the last luminaire in the line See Wiring the Luminaires on page 6 for details 5 Insert the luminaire through the hole in the ceiling 6 Using a 2 0 mm hex key tighten the silver screw on each of the three clamps see Navis 100 Features on page 4 for the locations of the clamp screws As you tighten each screw the clamp will automatically extend out to...

Page 19: ...onnects firmly with the three magnets on the base of the luminaire CAUTION It is very important that the trim plate is firmly attached to the luminaire with all three magnets engaged so that the trim plate does not detatch from the luminaire If the trim plate will not solidly attach to the luminaire verify the angle of the luminaire Loosen the yellow locking screw and repeat to step 2 making sure ...

Page 20: ...ivers and driver cards are compatible with White luminaires The F Drive R12 Chroma Card is compatible with RGBW luminaires 2 Verify that the driver is plugged in to a power source 3 Activate the Panic feature of the F Drive series driver Each luminaire will light at full power See the installation manual for your F Drive series driver for information about the Panic feature and the power up proced...

Page 21: ... matching the output from RGBW luminaires to 3000 K White and Fade to Warm luminaires When all four IRGB channels are set to 100 the output from the RGBW luminaire is 3000 K white light For complete information about configuring RDM control channels see the installation manual for your F Drive series driver DMX Channel Navis RGBW Luminaires Navis White and Fade to Warm Luminaires Direct IRGBW IRGB...

Page 22: ...Services for assistance Tool required Small flatblade screwdriver 1 Remove the magnetic trim plate from the base of the luminaire to expose the ceiling clamp screws and the locking screw 2 If necessary remove the finishing ring the secondary optic or both from the luminaire by sliding a small flatblade screwdriver between the edge of the part and the side of the luminaire and carefully prying the ...

Page 23: ... holder 6 If necessary reinstall the secondary optic the finishing ring or both by snapping the part into the lens holder 7 Replace the beam degree label on the base of the luminaire with the label from the replacement lens kit so that the luminaire is labeled correctly 8 Attach the magnetic trim plate to the base of the luminaire The trim plate should be centered on the base of the luminaire and ...

Page 24: ... the edge of the finishing ring and the side of the luminaire and carefully prying the ring loose 3 Remove the existing secondary optic by sliding a small flatblade screwdriver between one of the tabs on the secondary optic and the side of the luminaire and carefully prying the secondary optic loose see the previous graphic 4 Install the replacement secondary optic by snapping it into the lens hol...

Page 25: ...air from an air compressor set at a low setting can be used to blow through the vent holes and remove dust or other debris Dust buildup can cause overheating and premature shutdown All components can be cleaned using compressed oil free air as described above or a clean micro fiber cloth The use of any liquid cleaning solution is not recommended Inspect all mounting hardware for wear and if necess...

Page 26: ...6K1000 25 7496K1001 40 7496K1002 60 7496K1003 Magnetic Trim Plates Standard 7496A3006 Curve 7496A3007 Pinhole 7496A3008 Off set Slot 7496A3009 Secondary Optics Solite 7496K1004 Hex Louver 7496K1005 Frosted 7496K1006 Clear 7496K1007 Linear Spread 7496K1008 Wall Wash Conversion Kit Black 7496K1012 Lens Removal Tool 7496K1011 Part numbers listed are for the Black color option To order a different col...

Page 27: ...desired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and use...

Page 28: ... 852 2799 1220 Paris FR 33 1 4243 3535 Web etcconnect com Support support etcconnect com Contact etcconnect com contactETC 2020 Electronic Theatre Controls Inc Product information and specifications subject to change ETC intends this document to be provided in its entirety Trademark and patent info etcconnect com ip 7496M2100 Rev A Released 2020 03 ...