ENGLISH
29
SETTINGS > EXPERT MENU
BASIC programming: simplified mode for not professional
operators
EXPERT programming: complete programming including
functions for a more refined control and results.
After selecting, e.g. choosing EXPERT, at first display will still show Basic but as soon as moving to other steps it will change
to Expert, and vice versa.
Flow sensor enabled in case no water into sensor cell holder
(proximity switch will deactivate all outputs ensuring that no
extra chemical is added.
Manual temperature compensation 0÷100°C.
Press ◄► to show the environmental temperature.
Selecting Auto automatic compensation temperature/electrode
measurements, always giving the exact value against the
current temperature.
Press ◄► to show the environmental temperature to
calibrate sensor.
It adjusts the display save energy mode backlight level; touching any button will restore full 100%
display operative brightness.
Press ESC to return to MAIN MENU or Press ESC ESC to CONTINUOS MEASUREMENT display.
FACTORY SETTINGS: it restores factory default settings. To be used ONLY when parameters or
measurements are not responding correctly or when user wants to ensure to re-program from
zero. Not to abuse, continuous restoring can affect controller efficiency.
◄
►
◄
►
Once confirmed YES, display will be OFF for 1 second than will return to starting display.
CONTROLLER SETTINGS
Programming
BASIC
∗
EXPERT MENU
∗
CONTROLLER SETTINGS
Programming
EXPERT
∗
EXPERT MENU
∗
CONTROLLER SETTINGS
CONFIRM ?
YES
∗
EXPERT MENU
∗
CONTROLLER SETTINGS
CONFIRM ?
NO
∗
EXPERT MENU
∗
CONTROLLER SETTINGS
Factory Settings
YES
∗
EXPERT MENU
∗
CONTROLLER SETTINGS
Factory Settings
NO
∗
EXPERT MENU
∗
CONTROLLER SETTINGS
Backlight Low lev.
100%
∗
EXPERT MENU
∗
Select Menu
Settings
CONTROLLER SETTINGS
Probe Calibration
XX°C
∗
EXPERT MENU
∗
CONTROLLER SETTINGS
Temp. setting
XX°C
∗
EXPERT MENU
∗
CONTROLLER SETTINGS
Temp. mode
Auto
∗
EXPERT MENU
∗
CONTROLLER SETTINGS
Temp. mode
Manual
∗
EXPERT MENU
∗
CONTROLLER SETTINGS
Flow Sensor
Enabled
∗
EXPERT MENU
∗
CONTROLLER SETTINGS
Flow Sensor
Disabled
∗
EXPERT MENU
∗