press OK again and the values will be memorized.
The pump allows to select manual or automatic temperature compensation. To activate the automatic compensation is necessary
to connect a PT 100 thermal probe.
7.1.5 - Temperature compensation
In the case user decides to activate the automatic compensation
To shift use + or - buttons.
Continuing in the SETUP menu, pressing OK, it is possible to select temperature reading reading between Celsius and
Fahrenheit degrees (°C or °F).
7.1.4 - Temperature selection between Celsius and Fahrenheit degrees
Pressing OK to confirm and to save the choice.
of the temperature there's no need of additional operations because the
To select among manual or automatic (OFF or ON) use the
+ or - buttons. Once the desired mode is select press OK to confirm.
will flash the default temperature value i.e. 25°C. Using + and - buttons
probe.
pump will automatically measure the temperature through the thermal
on the display OFF icon will flash, pressing OK button, on the display
On other hand when OFF (manual compensation) needs to be selected:
it is possible to change this value. When the desired value is reached
When a level sensor is needed to be connected, the
LEVEL
warning will
sensor this icon will appear.
After the password has been determined, it is possible to set up the
type of sensor that is necessary to install the pump:
7.1.3 - Choice of Input Level/Flow
appear, on the other hand when it is necessary to connect a proximity