35
•
ENGLISH
6.6 - PARAMETERS AND FUNCTIONS LAYOUT (Factory default - pH)
4 mA
20 mA
05:00 m:s
7,2
0,1
Acid
°C
Manual - 25°C
00:03 m:s
DEFAULT
0,00
14,00
99:59 h:m
BASIC
pH
Disable
-------
Manual
Se 1pH
-------
Calibration check 4 mA
Calibration check 20 mA
Delay exit calibration menu
Setpoint setting
Hysteresis setting
Choice of the type of intervention
Chosen thermal selection (°C or °F)
Temperature compensation selection (manual - auto)
Delay at powering on
FUNCTIONS
Minimum alarm point
Maximum alarm point
Over-dosing alarm value
Choice of the type of menu: BASIC and FULL (expert user)
Selection measures to control (pH, RX or Chlorine)
Six figures numerical password
Second point of calibration procedure
Manual or proportional intervention selection
Definition of beginning intervention value "AUTO"
First point of calibration procedure
0÷40°C
6A (resistive load) 1A (inductive load)
4 - 20 mA (dynamic 0...500 ohm)
VALUE
0÷100°C (0,1°C)
0÷14 (0,01 pH)
-1000 ÷ +1400 (±1 mV)
0÷2; 0÷20; 0÷200; 0÷2000 (0,1 ppm)
6.7 - TYPICAL CHARACTERISTICS
Temperature
Max current relay output
Current output
PARAMETER
Temperature measure PT100
pH measure
RX (mV) measure
Chlorine measure