![ETAS XETK-S30.0 User Manual Download Page 16](http://html.mh-extra.com/html/etas/xetk-s30-0/xetk-s30-0_user-manual_2431143016.webp)
ETAS
Introduction
XETK-S30.0 - User’s Guide
16
3.2
Features
• Measurement interface:
– 3.3 V DAP output levels, 5.0 V tolerant DAP input
– Configurable DAP interface clock speed: 50 MHz, 100 MHz
– Pinless startup protocol for XETK recognition and data acquisition
triggering
• Calibration:
– Microcontroller capability of internal Flash emulation can be used
– XETK powers Emulation Device RAM (for calibration purpose)
– Supports “Start on Any Page”
• Supports special coldstart mechanism (“Calibration Wake Up”):
– Calibration Wake Up: Wake up mechanism to wake up the power sup-
ply of the ECU via the Calibration Wake up pin
– Pull CalWakeUp until Startup Handshake: duration of the Wake up
mechanism is configurable
• ECU flashing via XETK
– Braindead flashing under ProF control
• Permanent storage of configuration in EEPROM
• Fast Ethernet Interface:
– Direct connection to PC
– Open XCP on Ethernet Protocol
– Supports a variety of standard applications
• “ETK Drivers and Tools” update to support ETAS software tools (INCA,
XCT)
• Firmware update (programming of the logic device) through HSP soft-
ware service packs; removal of XETK or ECU is not necessary
• Mounting possibilities inside or on top of ECU
• Temperature range suitable for automotive application
For more technical data on the XETK-S30.0 consult the chapter “Technical
Data” on page 32.